MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2009.01.009

Медицинская библиотека · The Knee · 2009

Spontaneous late dislocation of the high flexion tibial insert after Genesis II total knee arthroplasty. A case report.

Rutten S G M, Janssen R P A

Клинический случайСтатьяПеревод в очереди

Аннотация

We present the first case of late spontaneous dislocation of a high flexion polyethylene insert after Genesis II total knee arthroplasty. Dislocation of the fixed insert occurred at 14 months post surgery while walking down a steep aircraft staircase. The total knee arthroplasty had been uneventful till that moment. The clinical presentation, possible causes and management are discussed. A surgical error, failure to remove a posterior femoral osteophyte, seems the most probable cause for the late insert dislocation in our case.

Для цитирования: Rutten S G M, Janssen R P A. Spontaneous late dislocation of the high flexion tibial insert after Genesis II total knee arthroplasty. A case report.. The Knee. 2009. DOI: 10.1016/j.knee.2009.01.009.