MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-024-05692-w

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2025

Treatment of both bone forearm fractures with 2.7 mm plates: a non-inferiority study.

Harrington Michael C, Nourie Blake, Perim Dana, Ratanpal Amit, Kalyanasundaram Gokul, Marinello Patrick

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the effectiveness of 2.7 mm plates in treating both bone forearm fractures (BBFFs) compared to the current gold standard of 3.5 mm fixation. More specifically, to determine if 2.7 mm plates are non-inferior to the current standard of 3.5 mm plates.

DESIGN

Retrospective including patients from 2016-2021.

SETTING

Single institution, level-1 trauma academic medical center.

PATIENTS/

PARTICIPANTS

77 patients met inclusion criteria, 58 patients underwent fixation with 3.5 mm plates and 19 underwent fixation with 2.7 mm plates.

INTERVENTION: Plate osteosynthesis with either 2.7 mm or 3.5 mm plate instrumentation.

MAIN OUTCOME MEASURE: Maintenance of reduction and achievement of fracture union.

RESULTS

Among 77 total patients, 19 received 2.7 mm plates and 58 received 3.5 mm plates. There was no difference in age and BMI between groups, but the 2.7 mm group had fewer males (47% vs 79%, p = 0.02). Primary end points of achievement of union (89.5% vs. 79.3%, p = 0.39) and maintenance of reduction (100% vs. 94.8%, p = 0.99), and secondary end points of implant removal (15.8% vs. 13.8%, p = 0.79), return to the operating room (OR) (5.3% vs. 5.2%, p = 0.63), and minor complications (0% vs. 6.9%, p = 0.99) were similar between the 2.7 mm and 3.5 mm groups.

CONCLUSION

This study challenges the current standard of ORIF using 3.5 mm plates for diaphyseal forearm fractures. 2.7 mm plating resulted in at least equivocal achievement of fracture union and thus may be more efficacious given previous studies showing lower refracture risks after implant removal.

LEVEL OF EVIDENCE: Level III, retrospective cohort study.

Для цитирования: Harrington Michael C, Nourie Blake, Perim Dana, Ratanpal Amit, Kalyanasundaram Gokul, Marinello Patrick. Treatment of both bone forearm fractures with 2.7 mm plates: a non-inferiority study.. Archives of orthopaedic and trauma surgery. 2025. DOI: 10.1007/s00402-024-05692-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.