Opportunistic osteoporosis screening using CT-based Hounsfield units: a machine learning approach for preoperative spine surgery planning.

Hiyama Akihiko, Sakai Daisuke, Katoh Hiroyuki, Sato Masato, Watanabe Masahiko

СтатьяПеревод в очереди

Аннотация

PURPOSE: Opportunistic assessment of vertebral bone quality using Hounsfield Units (HU) on preoperative computed tomography (CT) may complement dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. We developed a CT-based framework to predict osteoporosis from HU and basic demographics, restricting model development to cases with consistent HU–DXA agreement (“non-deviant”; residual within ± 1 SD of the axial HU–lowest T-score regression).

METHODS

We retrospectively reviewed 162 patients (2018–2025) who underwent lumbar CT and DXA. HU was measured at L1–L4 using axial (three-slice) and sagittal (single-slice) methods; sagittal S1 HU was also obtained. Residual filtering retained 123 non-deviant cases. An XGBoost classifier used 26 features (21 HU measures plus age, sex, height, weight, BMI) and was evaluated in three stratified 80/20 splits (AUC, accuracy, F1, sensitivity, specificity). Feature importance was assessed.

RESULTS

In the non-deviant cohort (n = 123), both axial and sagittal HU values showed strong correlations with DXA lowest T-score (ρ = 0.820 and ρ = 0.766, respectively; both p < 0.001). The XGBoost model achieved an average AUC of 0.804 ± 0.067, sensitivity of 0.857 ± 0.143, specificity of 0.759 ± 0.128, accuracy of 0.787 ± 0.061, and F1 score of 0.694 ± 0.048. HU measurements at L3 and L4, sex, body weight, and height were among the top predictive features.

CONCLUSIONS

In a carefully selected cohort demonstrating a stable HU–lowest T-score relationship, both axial and sagittal HU measurements demonstrated strong correlations with DXA lowest T-score, supporting their use as surrogate indicators of bone quality. The XGBoost model, trained on CT-derived HU values and demographic data, exhibited moderate classification performance within the non-deviant subset. These findings support the clinical utility of HU-based opportunistic screening as a triage approach to prompt confirmatory assessment and perioperative bone health optimization, particularly in settings where DXA is unavailable. These results represent proof-of-concept performance in HU–DXA–concordant cases and may not generalize to unfiltered populations.

Для цитирования: Hiyama Akihiko, Sakai Daisuke, Katoh Hiroyuki, Sato Masato, Watanabe Masahiko. Opportunistic osteoporosis screening using CT-based Hounsfield units: a machine learning approach for preoperative spine surgery planning.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2026. DOI: 10.1007/s00586-026-09782-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.