MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-016-1080-0

Медицинская библиотека · Annals of nuclear medicine · 2016

18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity.

Idolazzi Luca, Salgarello Matteo, Gatti Davide, Viapiana Ombretta, Vantaggiato Elisabetta, Fassio Angelo, Adami Silvano, Rossini Maurizio

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Aim of the current study was to evaluate the relationships between the findings of 18F-fluoride PET/CT (F-PET/CT) reflecting osteo-proliferative processes and the clinical indexes related to the disease activity. The clinical indexes are Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) and Ankylosing Spondylitis Disease Activity Score (ASDAS).

METHODS

We studied 29 AS patients aged 26-69 years with a wide range of disease activity using F-PET/CT. The number of regions of high bone turnover or osteoarthritis features at the spine and at sacroiliac joints was counted.

RESULTS

The number of F-PET/CT positive sites was significantly higher in patients with severe functional impairment and higher disease activity and it was positively related to both BASDAI (r = 0.336; P = 0.036) and ASDAS (r = 0.408; P = 0.014) while the number of degenerative features (osteoarthritis) was related neither with functional impact nor with disease activity.

CONCLUSIONS

With a single examination, F-PET/CT accurately identifies the functional impairment and the clinical involvement of AS. The good correlation we found between the number of F-PET/CT positive sites and disease activity candidates this technique also for follow-up of AS.

Для цитирования: Idolazzi Luca, Salgarello Matteo, Gatti Davide, Viapiana Ombretta, Vantaggiato Elisabetta, Fassio Angelo, Adami Silvano, Rossini Maurizio. 18F-fluoride PET/CT for detection of axial involvement in ankylosing spondylitis: correlation with disease activity.. Annals of nuclear medicine. 2016. DOI: 10.1007/s12149-016-1080-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.