MedElevator Войти в исследования
← Поиск публикаций

DOI 10.6061/clinics/2016(06)06

Медицинская библиотека · Clinics (Sao Paulo, Brazil) · 2016

Application of bioabsorbable screw fixation for anterior cervical decompression and bone grafting.

Zhao Bo, Qiu Xiaowen, Wang Dong, Li Haopeng, He Xijing

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To examine the application of bioabsorbable screws for anterior cervical decompression and bone grafting fixation and to study their clinical effects in the treatment of cervical spondylosis.

METHODS

From March 2007 to September 2012, 56 patients, 36 males and 20 females (38-79 years old, average 58.3±9.47 years), underwent a novel operation. Grafts were fixed by bioabsorbable screws (PLLA, 2.7 mm in diameter) after anterior decompression. The bioabsorbable screws were inserted from the midline of the graft bone to the bone surface of the upper and lower vertebrae at 45 degree angles. Patients were evaluated post-operatively to observe the improvement of symptoms and evaluate the fusion of the bone. The Japanese Orthopaedic Association (JOA) score was used to evaluate the recovery of neurological functions.

RESULTS

All screws were successfully inserted, with no broken screws. The rate of symptom improvement was 87.5%. All of the grafts fused well with no extrusion. The average time for graft fusion was 3.8±0.55 months (range 3-5 months). Three-dimensional reconstruction of CT scans demonstrated that the grafts fused with adjacent vertebrae well and that the screws were absorbed as predicted. The MRI findings showed that the cerebrospinal fluid was unobstructed. No obvious complications appeared in any of the follow-up evaluations.

CONCLUSIONS

Cervical spondylosis with one- or two-level involvement can be effectively treated by anterior decompression and bone grafting with bioabsorbable screw fixation. This operative method is safe and can avoid the complications induced by metal implants.

Для цитирования: Zhao Bo, Qiu Xiaowen, Wang Dong, Li Haopeng, He Xijing. Application of bioabsorbable screw fixation for anterior cervical decompression and bone grafting.. Clinics (Sao Paulo, Brazil). 2016. DOI: 10.6061/clinics/2016(06)06.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.