Van Rysselberghe Noelle L, Seltzer Ryan, Lawson Taylor A, Kuether Justin, White Parker, Grisdela Phillip, Daniell Hayley, Amirhekmat Arya, Merchan Nelson, Seaver Thomas, Samineni Aneesh, Saiz Augustine, Ngo Daniel, Dorman Clark, Epner Eden, Svetgoff Reese, Terle Megan, Lee Mark, Campbell Sean, Dikos Gregory, Warner Stephen, Achor Timothy, Weaver Michael J, Tornetta Paul, Scolaro John, Wixted John J, Weber Timothy, Bellino Michael J, Goodnough L Henry, Gardner Michael J, Bishop Julius A

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare clinical and radiographic outcomes after retrograde intramedullary nailing (rIMN) versus locked plating (LP) of "extreme distal" periprosthetic femur fractures, defined as those that contact or extend distal to the anterior flange.

DESIGN

Retrospective review.

SETTING

Eight academic level I trauma centers.

PATIENT SELECTION CRITERIA: Adult patients with periprosthetic distal femur fractures at or distal to the anterior flange (OTA/AO 33B-C[VB1]) treated with rIMN or LP.

OUTCOME MEASURES AND COMPARISONS: The primary outcome was reoperation to promote healing or to treat infection (reoperation for elective removal of symptomatic hardware was excluded from this analysis). Secondary outcomes included nonunion, delayed union, fixation failure, infection, overall reoperation rate, distal femoral alignment, and ambulatory status at final follow-up. Outcomes were compared between patients treated with rIMN or LP.

RESULTS

Seventy-one patients treated with rIMN and 224 patients treated with LP were included. The rIMN group had fewer points of fixation in the distal segment (rIMN: 3.5 ± 1.1 vs. LP: 6.0 ± 1.1, P < 0.001) and more patients who were allowed to weight-bear as tolerated immediately postoperatively (rIMN: 45%; LP: 9%, P < 0.01). Reoperation to promote union and/or treat infection was 8% in the rIMN group and 16% in the LP group ( P = 0.122). There were no significant differences in nonunion ( P > 0.999), delayed union ( P = 0.079), fixation failure ( P > 0.999), infection ( P = 0.084), or overall reoperation rate ( P > 0.999). Significantly more patients in the rIMN group were ambulatory without assistive devices at final follow-up (rIMN: 35%, LP: 18%, P = 0.008).

CONCLUSIONS

rIMN of extreme distal periprosthetic femur fractures has similar complication rates compared with LP, with a possible advantage of earlier return to weight-bearing. Surgeons can consider this treatment strategy in all fractures with stable implants and amenable prosthesis geometry, even extreme distal fractures.

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Van Rysselberghe Noelle L, Seltzer Ryan, Lawson Taylor A, Kuether Justin, White Parker, Grisdela Phillip, Daniell Hayley, Amirhekmat Arya, Merchan Nelson, Seaver Thomas, Samineni Aneesh, Saiz Augustine, Ngo Daniel, Dorman Clark, Epner Eden, Svetgoff Reese, Terle Megan, Lee Mark, Campbell Sean, Dikos Gregory, Warner Stephen, Achor Timothy, Weaver Michael J, Tornetta Paul, Scolaro John, Wixted John J, Weber Timothy, Bellino Michael J, Goodnough L Henry, Gardner Michael J, Bishop Julius A. Retrograde Intramedullary Nailing Versus Locked Plating for Extreme Distal Periprosthetic Femur Fractures: A Multicenter Retrospective Cohort Study.. Journal of orthopaedic trauma. 2024. DOI: 10.1097/bot.0000000000002730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.