MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-024-05418-z

Медицинская библиотека · Journal of orthopaedic surgery and research · 2025

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

Shi Yan, Zhou Junlin

СтатьяСравнительное исследованиеКлинический случайПеревод в очереди

Аннотация

BACKGROUND

Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

METHODS

Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

RESULTS

The displacement of the distal humerus with intramedullary nail fixation was more obvious than that of the distal humerus with bone plate fixation, and the resistance of intramedullary nail fixation was less than that of bone plate fixation under the same stress load. Maximum stress on the screw when adopting the intramedullary nail fixation was smaller than that when adopting the internal fixation with the internal fixation plates. The strain data indicate that the strain of both the fixation device and the bone when adopting the internal fixation with the intramedullary nails is less than that when adopting the internal fixation with the internal fixation plates.

CONCLUSIONS

Biomechanical analysis demonstrated that for complex fracture types with osteoporosis intramedullary nail system without opening the fracture had better stress dispersion than internal fixation plates with open reduction, and the risk of failure of central fixation was lower.

Для цитирования: Shi Yan, Zhou Junlin. Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.. Journal of orthopaedic surgery and research. 2025. DOI: 10.1186/s13018-024-05418-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.