MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1123/jab.2024-0283

Медицинская библиотека · Journal of applied biomechanics · 2025

Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation.

Bonfiglio Alessandro, Farella Elisabetta, Bongers Raoul M

СтатьяПеревод в очереди

Аннотация

Inertial Measurement Units (IMUs) enable accurate estimation of anatomical joint angles but require a sensor-to-segment calibration. Literature has presented several algorithms that address this gap; however, adequately comparing calibration performance is not trivial. This study compares 3 calibration methods: N-pose calibration (NP), functional calibration (FC), and manual alignment (MA) to estimate 3D wrist joint angles during single-plane and multiplane tasks. Thirteen healthy participants were instrumented with IMUs and optical markers to compute the range of motion error (ε), root mean squared error, and offset between the joint angles from the optical reference and each IMU calibration (NP, FC, and MA) as dependent variables. We then performed 3-way repeated-measures analyses of variance on each dependent variable to evaluate interactions between calibrations, tasks, and joint axes. NP showed the worst root mean squared error (8.34° [7.41°]) performance in the calibration main effect (η2G = .095) and calibration × tasks interaction (η2G = .121). In an exploratory analysis, FC performed best (main effect root mean squared error = 6.52° [4.47°]) in the offset calibration × axes interaction in single-plane (η2G = .160) tasks. Therefore, we recommend FC to optimally perform wrist calibration and against NP. These findings are viable in aiding the development of portable IMU-based clinical motion-tracking devices.

Для цитирования: Bonfiglio Alessandro, Farella Elisabetta, Bongers Raoul M. Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Wrist Joint Angles Estimation.. Journal of applied biomechanics. 2025. DOI: 10.1123/jab.2024-0283.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.