MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2017.3.peds16604

Медицинская библиотека · Journal of neurosurgery. Pediatrics · 2017

Analysis and interrater reliability of pB-C2 using MRI and CT: data from the Park-Reeves Syringomyelia Research Consortium on behalf of the Pediatric Craniocervical Society.

Hankinson Todd C, Tuite Gerald F, Moscoso Dagmara I, Robinson Leslie C, Torner James C, Limbrick David D, Park Tae Sung, Anderson Richard C E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE The distance to the ventral dura, perpendicular to the basion to C2 line (pB-C2), is commonly employed as a measure describing the anatomy of the craniovertebral junction. However, both the reliability among observers and the clinical utility of this measurement in the context of Chiari malformation Type I (CM-I) have been incompletely determined. METHODS Data were reviewed from the first 600 patients enrolled in the Park-Reeves Syringomyelia Research Consortium with CM-I and syringomyelia. Thirty-one cases were identified in which both CT and MRI studies were available for review. Three pediatric neurosurgeons independently determined pB-C2 values using common imaging sequences: MRI (T1-weighted and T2-weighted with and without the inclusion of retro-odontoid soft tissue) and CT. Values were compared and intraclass correlations were calculated among imaging modalities and observers. RESULTS Intraclass correlation of pB-C2 demonstrated strong agreement between observers (intraclass correlation coefficient [ICC] range 0.72-0.76). Measurement using T2-weighted MRI with the inclusion of retro-odontoid soft tissue showed no significant difference with measurement using T1-weighted MRI. Measurements using CT or T2-weighted MRI without retro-odontoid soft tissue differed by 1.6 mm (4.69 and 3.09 mm, respectively, p < 0.05) and were significantly shorter than those using the other 2 sequences. Conclusions pB-C2 can be measured reliably by multiple observers in the context of pediatric CM-I with syringomeyelia. Measurement using T2-weighted MRI excluding retro-odontoid soft tissue closely approximates the value obtained using CT, which may allow for the less frequent use of CT in this patient population. Measurement using T2-weighted MRI including retro-odontoid soft tissue or using T1-weighted MRI yields a more complete assessment of the extent of ventral brainstem compression, but its association with clinical outcomes requires further study.

Для цитирования: Hankinson Todd C, Tuite Gerald F, Moscoso Dagmara I, Robinson Leslie C, Torner James C, Limbrick David D, Park Tae Sung, Anderson Richard C E. Analysis and interrater reliability of pB-C2 using MRI and CT: data from the Park-Reeves Syringomyelia Research Consortium on behalf of the Pediatric Craniocervical Society.. Journal of neurosurgery. Pediatrics. 2017. DOI: 10.3171/2017.3.peds16604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.