MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000010787

Медицинская библиотека · The Journal of craniofacial surgery · 2024

Evaluation of the Effect of Pre-bent Z-shaped Titanium Plate on Narrowing of Zygomatic Arch in L-shaped Reduction Malarplasty.

Shu Kai-Yi, Li Xi-Yuan, Zhao Jiu-Li, Zhang Zhi-Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Pre-bent titanium plates are widely used for internal fixation in L-shaped zygomatic reduction. The aim is to evaluate the effect of pre-bent Z-shaped titanium plate on the narrowing of the zygomatic arch in L-shaped reduction malarplasty.

METHODS

Thirty cosmetic female patients were selected and scanned using computed tomography (CT). The CT images of pre-operation (T1) and post-operation(T2) were re-established through MIMICS26.0 (Materialise). After the 2 images were registered based on the skull base, the narrowing distance (ZRN) at the posterior end of the free zygomatic arch, as well as the preoperative and postoperative cross-sectional dimensions of the zygomatic arch, were measured. The ZRN and the altitude of the pre-bent titanium plate (TA) were compared using an independent t test, and their correlation was also analyzed using the Pearson coefficient. The preoperative and postoperative longest diameter (L1) and shortest diameter (L2) of the posterior zygomatic arch were compared using a paired t test.

RESULTS

The TA was 3.80±0.82 mm and the ZRN was 3.21±0.82 mm. The difference value was 0.59±0.41 mm, which was statistically significant. TA showed a strong correlation with ZRN ( r =0.916, P =0.002). The L1 and L2 of the zygomatic arch root were slightly reduced postoperatively.

CONCLUSION

The pre-bent Z-shaped titanium plate does not completely correspond to the zygomatic arch narrowing distance in the actual application of L-shaped reduction malarplasty. However, it can control the narrowing distance of the zygomatic arch predictably, and achieve satisfactory surgical outcomes.

Для цитирования: Shu Kai-Yi, Li Xi-Yuan, Zhao Jiu-Li, Zhang Zhi-Yong. Evaluation of the Effect of Pre-bent Z-shaped Titanium Plate on Narrowing of Zygomatic Arch in L-shaped Reduction Malarplasty.. The Journal of craniofacial surgery. 2024. DOI: 10.1097/scs.0000000000010787.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.