MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-019-02397-4

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019

Clinical outcomes of dynamic hip screw fixation of intertrochanteric fractures: comparison with additional anti-rotation screw use.

Kim Chul-Ho, Chang Jae Suk, Kim Ji Wan

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Hip screw cutout is among the most common causes of intertrochanteric fracture fixation failure using dynamic hip screws (DHS). This study aimed to evaluate the effect of using an additional anti-rotation screw on hip screw migration or cutout in intertrochanteric fracture fixation.

MATERIALS AND

METHODS

We screened 488 patients with unilateral fragile intertrochanteric fractures treated with DHS between January 2001 and March 2016. The inclusion criteria were as follows: (1) age ≥ 50 years; (2) low-energy injury; (3) follow-up of at least 6 months; and (4) short barrel plate used in the operation. The exclusion criteria were as follows: (1) combination with other fracture; or (2) pathological fracture. Subsequently, 166 patients were enrolled; of them, 128 underwent surgery using DHS with an additional screw (Group 1) and 38 patients underwent surgery without an additional screw (Group 2). We compared the postoperative results and clinical outcomes while focusing on screw migration and cutout. Furthermore, we investigated the risk factors for lag screw migration.

RESULTS

Bone union was achieved in 160 patients (96.4%) without secondary intervention. Two patients (1.6%) in Group 1 and 1 (2.6%) in Group 2 developed screw cutout, while 18 (14.1%) in Group 1 and 12 (31.6%) in Group 2 developed screw migration. Thus, Group 2 demonstrated a higher screw migration rate. Multiple logistic regression analysis revealed that the additional anti-rotation screw was the most important factor in preventing screw migration (P = 0.019).

CONCLUSION

The additional anti-rotation screw reduced the lag screw migration rate following DHS surgery for intertrochanteric fractures.

LEVEL OF EVIDENCE: Level IV, retrospective series.

Для цитирования: Kim Chul-Ho, Chang Jae Suk, Kim Ji Wan. Clinical outcomes of dynamic hip screw fixation of intertrochanteric fractures: comparison with additional anti-rotation screw use.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2019. DOI: 10.1007/s00590-019-02397-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.