MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/cia.s246998

Медицинская библиотека · Clinical interventions in aging · 2020

The Role of Hip Abductor Strength in Identifying Older Persons at Risk of Falls: A Diagnostic Accuracy Study.

Gafner Simone Chantal, Bastiaenen Caroline Henrice Germaine, Ferrari Serge, Gold Gabriel, Trombetti Andrea, Terrier Philippe, Hilfiker Roger, Allet Lara

СтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

Early detection of fall risk in persons older than 65 is of clinical relevance, but the diagnostic accuracy of currently used functional tests (eg short physical performance battery [SPPB] and timed up and go test [TUG]) to assess older persons' fall risks remains moderate. Recent literature highlights the importance of strong hip abductors to prevent falls. We thus aimed to assess the diagnostic accuracy of hip abductor strength measures to assess older persons' fall risks.

METHODS

Hip abductor maximum voluntary isometric strength (ABD MVIS), rate of force generation (ABD RFG), and the SPPB and TUG functional fall risk assessments were assessed in 60 persons aged over 65 years (82.0 ± 6.1 years). The diagnostic accuracy (area under the curve [AUC], sensitivity [sens], specificity [spec], positive predictive value [PPV], negative predictive value [NPV], and positive and negative likelihood ratios [LR+, LR-]) was evaluated at a clinically important 90% sensitivity level. Cut-off values for clinical use were calculated.

RESULTS

In our population, hip ABD MVIS (AUC 0.8, sens 90.6%, spec 57.1%, PPV 70.7%, NPV 84.2%, LR+ 2.1, LR- 0.2, and cut-off value ≤ 1.1 N/kg) and hip ABD RFG (AUC 0.8, sens 90.6%, spec 46.4%, PPV 65.9%, NPV 81.3%, LR+ 1.7, LR- 0.2, and cut-off ≤ 8.47 N/kg/s) show diagnostic accuracy comparable to other fall risk assessments (SPPB and TUG) and a high net sensitivity when used in a test battery.

CONCLUSION

Hip ABD MVIS or RFG shows good diagnostic accuracy to differentiate between older fallers and nonfallers compared to the chosen external criterion history of falls. The high net sensitivity when hip ABD MVIS or RFG is combined with currently used fall risk assessments shows promise in contributing value to a test battery and should be investigated further in longitudinal studies.

Для цитирования: Gafner Simone Chantal, Bastiaenen Caroline Henrice Germaine, Ferrari Serge, Gold Gabriel, Trombetti Andrea, Terrier Philippe, Hilfiker Roger, Allet Lara. The Role of Hip Abductor Strength in Identifying Older Persons at Risk of Falls: A Diagnostic Accuracy Study.. Clinical interventions in aging. 2020. DOI: 10.2147/cia.s246998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.