BACKGROUND

Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA.

METHODS

Thirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method.

RESULTS

Fluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans.

CONCLUSION

Asymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings.

LEVEL OF EVIDENCE: Diagnostic Level IV.

Для цитирования: Jennings Jason M, Czuczman Gregory J, Johnson Roseann M, Dennis Douglas A. Metal Artifact Reduction Sequence Magnetic Resonance Imaging Abnormalities in Asymptomatic Patients With a Ceramic-on-Ceramic Total Hip Replacement.. The Journal of arthroplasty. 2020. DOI: 10.1016/j.arth.2020.07.082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.