DOI 10.1016/j.oooo.2024.09.002
Comparison between 2- and 4-plate fixation in Le Fort I osteotomy: a mixed methods systematic review.
Аннотация
OBJECTIVE
Achieving postsurgical skeletal stability is crucial for successful outcomes and patient satisfaction. Precision maxillofacial surgery, which integrates precision techniques with minimally invasive approaches, is increasingly recognized for its potential to enhance long-term stability and reduce surgical risks and complications. This study aimed to comprehensively evaluate the impact of fixation techniques (2 vs 4 plates) during Le Fort I osteotomy in orthognathic surgery on skeletal stability. The main focus was to compare the stability achieved and potential risks of relapse between these two fixation methods.
MATERIAL AND
METHODS
A mixed-methods approach was employed, combining a systematic review, in silico analysis, and in vitro studies. The systematic review adhered to Joanna Briggs Institute methodology and Good Reporting of A Mixed Methods Study guidelines, focusing on comparative studies that evaluated skeletal stability as the primary outcome measure. In silico and in vitro analyses were conducted to assess the biomechanical principles and relapse risks associated with maxillary advancement using different fixation techniques.
RESULTS
The systematic review included three clinical trials, four finite element analysis studies, and two in vitro analyses. The meta-analysis revealed no significant difference in skeletal stability between the 2- and 4-plate fixation methods. However, biomechanical analysis showed an atypical increase in relapse risk with 2-plate fixation at 3 mm maxillary advancement, compared to a 10 mm advancement for 4-plate fixation.
CONCLUSIONS
While both 2- and 4-plate fixation methods are viable, the findings suggest that 4-plate fixation offers superior stability, particularly in cases of significant maxillary advancement, where 2-plate fixation showed an increased risk of relapse. Future research with larger sample sizes and addressing the biases identified in this study is needed to validate these findings and effectively guide clinical practice.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.