MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.202403052

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024

[Prospective study of three-dimensional-printed in vitro guide plates assisted hip arthroscopy in treatment of Cam-type femoroacetabular impingement].

Yang Dongqiang, Wei Songsong, Liu Yijun, Hu Yong

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

A prospective study was conducted to investigate the feasibility and effectiveness of three-dimensional printed in vitro guide plates assisted hip arthroscopy in the treatment of Cam-type femoroacetabular impingement (FAI).

METHODS

The clinical data of 25 patients with Cam-type FAI who met the selection criteria between December 2016 and September 2022 were collected. There were 13 males and 12 females with an average age of 42 years (range, 19-66 years). The disease duration ranged from 3 to 120 months, with an average of 22.2 months. The preoperative range of internal rotation-external rotation was (28.70±4.50)°, α angle was (69.04±0.99)°, visual analogue scale (VAS) score was 6.5±0.2, and modified Harris hip score (HHS) was 50.5±0.7. All patients were treated with hip arthroscopy assisted by three-dimensional printed in vitro guide plate. The occurrence of complications was observed postoperatively, α angle of the affected hip joint was measured on Dunn X-ray film, and the glenoid labrum injury was observed by MRI. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was calculated by three-dimensional CT+reconstruction. The effectiveness was evaluated by VAS score and modified HHS score.

RESULTS

Postoperative dorsalis pedis numbness occurred in 1 case, and the symptoms disappeared after 1 month of conventional drug treatment such as neurotrophy. Two cases of perineal skin injury occurred, and healed after symptomatic treatment. There was no male erectile dysfunction, deep incision infection, pulmonary embolism, or other serious complications occurred. The percentage of overlap between the Cam plasty area and the preoperative simulated grinding area was 81.6%-95.3%, with an average of 89.8%. All 25 patients were followed up 6-12 months, with an average of 8 months. At last follow-up, the range of internal rotation-external rotation was (40.10±2.98)°, α angle was (43.72±0.84)°, VAS score was 1.8±0.2, and the modified HHS score was 72.1±1.3, which significantly improved when compared with preoperative ones ( P<0.05).

CONCLUSION

The treatment of Cam-type FAI with three-dimensional printed in vitro guide plates assisted hip arthroscopy is safe and feasible, and can achieve good effectiveness.

Для цитирования: Yang Dongqiang, Wei Songsong, Liu Yijun, Hu Yong. [Prospective study of three-dimensional-printed in vitro guide plates assisted hip arthroscopy in treatment of Cam-type femoroacetabular impingement].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2024. DOI: 10.7507/1002-1892.202403052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.