MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7717/peerj.19766

Медицинская библиотека · PeerJ · 2025

Robotic evaluation of a 3D-printed scaffold for reconstruction of scapholunate interosseous ligament rupture: a biomechanical cadaveric study.

Quinn Alastair R J, Maharaj Jayishni N, Bindra Randy, Carr Amelia, Gomez Natividad, Fitzgerald Kaecee, Perevoshchikova Nataliya, Vaquette Cedryck, Pizzolato Claudio, Zheng Minghao, Lloyd David, Saxby David J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Rupture of the scapholunate (SL) interosseous ligament (SLIL) is a challenging injury to treat surgically due to the small and complex nature of the SL linkage. This study was a preliminary robotic assessment of the immediate biomechanical effects of a novel 3D-printed scaffold used to reconstruct the ruptured SLIL.

METHODS

Nine minimally loaded cadaveric wrists underwent robotically manipulated flexion-extension and radial-ulnar deviation under conditions of intact, transected, and reconstructed SLIL. Simulated radiographic measures (i.e., SL angle and SL gap) and three-dimensional SL gap across wrist motions were used to assess static and dynamic stability of the reconstructed SLIL.

RESULTS

Three cadaveric specimens produced complete results across all experimental conditions. Intact SL linkage had a SL angle comparable (but slightly lower) than normative literature values. Once the native SLIL was transected, SL angle disruption was evident, and largely restored once the scaffold was surgically installed. Similar results were seen for SL gap. Results of the dynamic three-dimensional SL gap indicated the scaffold restored dynamic stability to a limited extent.

CONCLUSION

Static and dynamic stability of the SL linkage was not compromised by surgical installation of the scaffold. Scaffold installation provided limited restoration of SL linkage towards native values; however, the small number of cadaveric specimens and minimal articular loading applied to the radiocarpal joint limits generalization. Overall, the scaffold may provide adequate mechanical fixation of the SL linkage and enable biological ingrowth of ligament.

Для цитирования: Quinn Alastair R J, Maharaj Jayishni N, Bindra Randy, Carr Amelia, Gomez Natividad, Fitzgerald Kaecee, Perevoshchikova Nataliya, Vaquette Cedryck, Pizzolato Claudio, Zheng Minghao, Lloyd David, Saxby David J. Robotic evaluation of a 3D-printed scaffold for reconstruction of scapholunate interosseous ligament rupture: a biomechanical cadaveric study.. PeerJ. 2025. DOI: 10.7717/peerj.19766.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.