MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2169/internalmedicine.7824-21

Медицинская библиотека · Internal medicine (Tokyo, Japan) · 2022

A Comparison of Line Blots, Enzyme-linked Immunosorbent, and RNA-immunoprecipitation Assays of Antisynthetase Antibodies in Serum Samples from 44 Patients.

Shinoda Koichiro, Okumura Maiko, Yamaguchi Satoshi, Matsui Atsushi, Tsuda Reina, Hounoki Hiroyuki, Suzuki Shigeaki, Tobe Kazuyuki

СтатьяПеревод в очереди

Аннотация

Objective To determine the differences between anti-aminoacyl tRNA synthetase (ARS) antibodies among line blots, enzyme-linked immunosorbent assay (ELISA) anti-ARS tests, and RNA-immunoprecipitation (IP) assays. Methods Sera from patients with confirmed or suspected antisynthetase syndrome (ASS) that were positive for either the anti-ARS test or the line-blot assay were used to perform an RNA-IP assay and ELISA to detect individual anti-ARS antibodies. Results Among the 44 patients, 10 were positive only in line-blot assays, 6 were positive only in the anti-ARS test, and 28 were positive in both assays. We compared the accuracy of these assays against the gold standard RNA-IP assay. The κ coefficient was 0.23 in the line-blot assay, but this increased to 0.75 when the cut-off was increased from 1+ to 2+. The κ coefficient was 0.73 in the anti-ARS test. The κ coefficient was 0.85 for positivity in both assays. Patients with ASS that was positive in an RNA-IP assay more frequently had mechanic's hand (62.1% vs. 20%: p=0.031), myositis (51.7 vs. 10%: p=0.028) and more ASS symptoms than those who were positive only in line-blot assays (3.48 vs. 2.2: p=0.019). Conclusions Clinicians need to understand the features of each assay and determine diagnoses by also considering clinical presentations. Diagnoses should not be judged based only on the results of line-blot assays due to the risk of a misdiagnosis from false positives.

Для цитирования: Shinoda Koichiro, Okumura Maiko, Yamaguchi Satoshi, Matsui Atsushi, Tsuda Reina, Hounoki Hiroyuki, Suzuki Shigeaki, Tobe Kazuyuki. A Comparison of Line Blots, Enzyme-linked Immunosorbent, and RNA-immunoprecipitation Assays of Antisynthetase Antibodies in Serum Samples from 44 Patients.. Internal medicine (Tokyo, Japan). 2022. DOI: 10.2169/internalmedicine.7824-21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.