MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.eclinm.2022.101542

Медицинская библиотека · EClinicalMedicine · 2022

Immune response and reactogenicity after immunization with two-doses of an experimental COVID-19 vaccine (CVnCOV) followed by a third-fourth shot with a standard mRNA vaccine (BNT162b2): RescueVacs multicenter cohort study.

Ascaso-Del-Rio Ana, García-Pérez Javier, Pérez-Olmeda Mayte, Arana-Arri Eunate, Vergara Itziar, Pérez-Ingidua Carla, Bermejo Mercedes, Castillo de la Osa María, Imaz-Ayo Natale, Riaño Fernández Ioana, Astasio González Oliver, Díez-Fuertes Francisco, Meijide Susana, Arrizabalaga Julio, Hernández Gutiérrez Lourdes, de la Torre-Tarazona Humberto Erick, Mariano Lázaro Alberto, Vargas-Castrillón Emilio, Alcamí José, Portolés Antonio, RescueVac study Group

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There is no evidence to date on immunogenic response among individuals who participated in clinical trials of COVID-19 experimental vaccines redirected to standard national vaccination regimens.

METHODS

This multicentre, prospective controlled cohort study included subjects who received a COVID-19 experimental vaccine (CVnCoV)(test group, TG) - and unvaccinated subjects (control group, CG), selected among individuals to be vaccinated according to the Spanish vaccination program. All study subjects received BNT162b2 as a standard national vaccination schedule, except 8 (from CG) who received mRNA-1273 and were excluded from immunogenicity analyses. Anti-RBD antibodies level and neutralising titres (NT50) against G614, Beta, Mu, Delta and Omicron variants were analysed. Reactogenicity was also assessed.

FINDINGS: 130 participants (TG:92; CG:38) completed standard vaccination. In TG, median (IQR) of anti-RBD antibodies after first BNT162b2 dose were 10740·0 BAU/mL (4466·0-12500) compared to 29·8 BAU/mL (14·5-47·8) in CG (p <0·0001). Median NT50 (IQR) of G614 was 2674·0 (1865·0-3997·0) in TG and 63·0 (16·0-123·1) in CG (p <0·0001). After second BNT162b2 dose, anti-RBD levels increased to ≥12500 BAU/mL (11625·0-12500) in TG compared to 1859·0 BAU/mL (915·4-3820·0) in CG (p <0·0001). NT50 was 2626·5 (1756·0-5472·0) and 850·4 (525·1-1608·0), respectively (p <0·0001). Variant-specific (Beta, Mu, Omicron) response was also assessed. Most frequent adverse reactions were headache, myalgia, and local pain. No severe AEs were reported.

INTERPRETATION: Heterologous BNT162b2 as third and fourth doses in previously suboptimal immunized individuals elicit stronger immune response than that obtained with two doses of BNT162b2. This apparent benefit was also observed in variant-specific response. No safety concerns arose.

FUNDING: Partly funded by the Institute of Health Carlos-III and COVID-19 Fund, co-financed by the European Regional Development Fund (FEDER) "A way to make Europe".

Для цитирования: Ascaso-Del-Rio Ana, García-Pérez Javier, Pérez-Olmeda Mayte, Arana-Arri Eunate, Vergara Itziar, Pérez-Ingidua Carla, Bermejo Mercedes, Castillo de la Osa María, Imaz-Ayo Natale, Riaño Fernández Ioana, Astasio González Oliver, Díez-Fuertes Francisco, Meijide Susana, Arrizabalaga Julio, Hernández Gutiérrez Lourdes, de la Torre-Tarazona Humberto Erick, Mariano Lázaro Alberto, Vargas-Castrillón Emilio, Alcamí José, Portolés Antonio, RescueVac study Group. Immune response and reactogenicity after immunization with two-doses of an experimental COVID-19 vaccine (CVnCOV) followed by a third-fourth shot with a standard mRNA vaccine (BNT162b2): RescueVacs multicenter cohort study.. EClinicalMedicine. 2022. DOI: 10.1016/j.eclinm.2022.101542.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.