MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pathol.2019.09.013

Медицинская библиотека · Pathology · 2020

High accuracy of HLA-B*27 genotyping by allele-specific real-time polymerase chain reaction in a heterogeneous population compared to flow cytometry and single nucleotide polymorphism detection assays.

Jang Helena S, Proos Annè, Koe Lisa, Anderson Janet, Fulton Richard, Fernando Suran L

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

HLA-B27 is a risk marker for ankylosing spondylitis and other associated seronegative spondyloarthropathies. We compared three methods of HLA-B*27 typing in a New South Wales (NSW) population: flow cytometry, rs4349859 single nucleotide polymorphism (SNP) detection assay, and allele-specific real-time polymerase chain reaction (RT-PCR) analysis of exons 2 and 3. Over a 5-month period, 543 samples underwent flow cytometric testing and RT-PCR high-resolution melt analysis of rs4349859 SNP and of exon 2 (5' fragment) and exon 3. In the third method, positive samples were further analysed with fluorescent resonance emission transfer (FRET) RT-PCR of exon 2 fragments, 2a and 2b. HLA-B*27 and other genotypes were confirmed by Sanger sequencing of a 600 base pair fragment of exons 2 and 3. In our cohort, the rs4349859 SNP method had 78.6% sensitivity and 98.7% specificity. Screening with exon 2 (5' fragment) and exon 3 RT-PCR provided 100% sensitivity. Further testing with exon 2a and 2b FRET RT-PCR produced 100% specificity. This cascade approach with allele-specific RT-PCR assays was able to differentiate all samples into HLA-B*27 subtypes. HLA-B*27 genotyping with allele-specific RT-PCR assays, to screen for and confirm HLA-B27 positive samples, was more sensitive and specific than flow cytometry and rs4349859 SNP assays. It is a potentially cost-effective method for differentiating HLA-B27 subtypes. Our cascade genetic testing approach is suitable for replacing the current flow cytometric HLA-B27 assay for the heterogeneous NSW population.

Для цитирования: Jang Helena S, Proos Annè, Koe Lisa, Anderson Janet, Fulton Richard, Fernando Suran L. High accuracy of HLA-B*27 genotyping by allele-specific real-time polymerase chain reaction in a heterogeneous population compared to flow cytometry and single nucleotide polymorphism detection assays.. Pathology. 2020. DOI: 10.1016/j.pathol.2019.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.