DOI 10.1136/annrheumdis-2013-203946

Медицинская библиотека · Annals of the rheumatic diseases · 2013

Quantitative syndesmophyte measurement in ankylosing spondylitis using CT: longitudinal validity and sensitivity to change over 2 years.

Tan Sovira, Yao Jianhua, Flynn John A, Yao Lawrence, Ward Michael M

СтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralПеревод в очереди

Аннотация

OBJECTIVES

Accurate measurement of syndesmophyte development and growth in ankylosing spondylitis (AS) is needed for studies of biomarkers and of treatments to slow spinal fusion. We tested the longitudinal validity and sensitivity to change of quantitative measurement of syndesmophytes using CT.

METHODS

We performed lumbar spine CT scans on 33 patients with AS at baseline, 1 year and 2 years. Volumes and heights of syndesmophytes were computed in four intervertebral disk spaces. We compared the computed changes to a physician's ratings of change based on CT scan inspection. Sensitivity to change of the computed measures was compared with that of the modified Stoke AS Spinal Score (radiography) and a scoring method based on MRI.

RESULTS

At years 1 and 2, respectively 24 (73%) and 26 (79%) patients had syndesmophyte volume increases by CT. At years 1 and 2, the mean (SD) computed volume increases per patient were, respectively 87 (186) and 201 (366) mm(3). Computed volume changes were strongly associated with the physician's visual ratings of change (p<0.0002 and p<0.0001 for changes at years 1 and 2, respectively). The sensitivity to change over 1 year was higher for the CT volume measure (1.84) and the CT height measure (1.22) than either the MRI measure (0.50) or radiography (0.29).

CONCLUSIONS

CT-based syndesmophytes measurements had very good longitudinal validity and better sensitivity to change than radiography or MRI. This method shows promise for longitudinal clinical studies of syndesmophyte development and growth.

Для цитирования: Tan Sovira, Yao Jianhua, Flynn John A, Yao Lawrence, Ward Michael M. Quantitative syndesmophyte measurement in ankylosing spondylitis using CT: longitudinal validity and sensitivity to change over 2 years.. Annals of the rheumatic diseases. 2013. DOI: 10.1136/annrheumdis-2013-203946.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.