MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12871-018-0678-2

Медицинская библиотека · BMC anesthesiology · 2019

Usefulness of Airway Scope for intubation of infants with cleft lip and palate-comparison with Macintosh laryngoscope: a randomized controlled trial.

Okumura Yoko, Okuda Masahiro, Sato Boku Aiji, Tachi Naoko, Hashimoto Mayumi, Yamada Tomio, Yamada Masahiro

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Airway Scope (AWS) with its plastic blade does not require a head-tilt or separate laryngoscopy to guide intubations. Therefore, we hypothesized that its use would reduce the intubation time (IT) and the frequency of airway complication events when compared with the use of Macintosh Laryngoscope (ML) for infants with cleft lip and palate (CLP).

METHODS

The parents of all patients provided written consents; we enrolled 40 infants with CLP (ASA-PS 1). After inducing general anesthesia using sevoflurane and rocuronium, we performed orotracheal intubations using either AWS (n = 20) or ML (n = 20), randomly. We define the duration between manual manipulation using cross finger for maximum mouth opening and the first raising motion of the chest following intubation by artificial ventilation as "IT;" further, the measured IT as primary outcomes. Airway complications were considered secondary outcomes. Moreover, we looked for associations between IT and the patient's characteristics: extensive clefts, age, height, and weight. We used the Mann-Whitney test and Fisher's exact probability test for statistical analysis; p < 0.05 was considered as statistically significant.

RESULTS

The mean IT was 31.5 ± 8.3 s in AWS group and 26.4 ± 8.9 s in ML group. Statistical significant difference was not found in IT between the two groups. The IT of AWS group was statistically related to extensive clefts. Airway complications were detected in ML group.

CONCLUSION

AWS could be useful for intubation of infants with CLP; it required IT similar to that required using ML, with a lower rate of airway complications.

TRIAL REGISTRATION: UMIN-CTR Registration number UMIN000024763 . Registered 8 November 2016.

Для цитирования: Okumura Yoko, Okuda Masahiro, Sato Boku Aiji, Tachi Naoko, Hashimoto Mayumi, Yamada Tomio, Yamada Masahiro. Usefulness of Airway Scope for intubation of infants with cleft lip and palate-comparison with Macintosh laryngoscope: a randomized controlled trial.. BMC anesthesiology. 2019. DOI: 10.1186/s12871-018-0678-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.