OBJECTIVE

We previously reported the questionable result of reoperation using metal-on-polyethylene (MoP) bearing after the fracture of the ceramic component. After the report, we abandoned the use of MoP; instead, we used ceramic-on-ceramic (CoC) bearing. This report aimed to present the outcome of reoperation to CoC bearing after ceramic component failures along with the longer-term outcome of the previously reported cohort with an MoP bearing.

RESULTS

The mean follow-up of the MoP cohort was extended from 4.3 years to 8.8 years. Metallosis had occurred in three of nine patients of the previous cohort, which all required re-reoperations. Two hips from 11 patients with revision to CoC had re-reoperations due to ceramic liner fracture and non-union of the osteotomized fragment, respectively. No metallosis and wear occurred in the cohort revised with CoC articulation. Otherwise, there were no adverse changes in radiographs and no impairment in functions.

METHODS

We conducted an extended prospective evaluation of a previous cohort consisting of six head fractures and three liner fractures. In this cohort, the patients underwent a bearing change to metal-on-polyethylene. Additionally, we retrospectively analyzed 11 cases of third-generation ceramic bearing fractures, comprising nine head fractures and two liner fractures. These cases were subsequently treated with a bearing change to fourth-generation CoC. We assessed clinical and radiological outcomes, including complication rates, in both groups.

CONCLUSION

We recommend the latest CoC as the bearing of choice in reoperation after the fracture of ceramic components. In the case of an MoP bearing after the ceramic component fracture, the risk of metallosis seemed high in the early postoperative period.

Для цитирования: Kim Hong Seok, Lee Han Jin, Lee Soong Joon, Yoo Jeong Joon. Ceramic-on-Ceramic or Metal-on-Polyethylene: The Bearing of Choice after Ceramic Component Fracture in Total Hip Arthroplasty along with Concise Follow-Up of the Previous Cohort.. Orthopaedic surgery. 2023. DOI: 10.1111/os.13889.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.