MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5137/1019-5149.jtn.16203-15.1

Медицинская библиотека · Turkish neurosurgery · 2017

Comparison of the Rigid Rod System with Modular Plate with the Finite Element Analysis in Short-Segment Posterior Stabilization in the Lower Lumbar Region.

Yaldiz Can, Ozkal Birol, Guvenc Yahya, Senturk Salim, Erbulut Deniz, Zafarparandah Iman, Yaman Onur, Solaroglu Ihsan, Ozer Fahir

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: Many studies are available in the literature on posterior spinal instrumentation, though the use of a rod and a plate is still controversial in the literature. In this study, a finite element analysis of the strength and superiority of modular rigid plate and rod systems, which are used in the lower lumbar region, in comparison with each other was used.

MATERIAL AND

METHODS

A Ti6Al4V (Grade 5) titanium biocompatible alloy anterior plate was used for the lumbar spine fixation device, and a finite element analysis was conducted on the human lumbar spine model. In this study, an intact spine, a rigid system fixed with a rod, and modular plate systems were evaluated at flexion, extension, lateral bending, and axial rotation.

RESULTS

They did not show statistically significant superiority over one another in terms of limitations in movement during the range of motion exercises and rigidity.

CONCLUSION

The posterior rigid stabilization system and novel stabilization system do not have a significant superiority over one another. Equivalent results in the limitation of movement and rigidity allow for the use of these systems for short-segment posterior spinal instrumentation with the same indications.

Для цитирования: Yaldiz Can, Ozkal Birol, Guvenc Yahya, Senturk Salim, Erbulut Deniz, Zafarparandah Iman, Yaman Onur, Solaroglu Ihsan, Ozer Fahir. Comparison of the Rigid Rod System with Modular Plate with the Finite Element Analysis in Short-Segment Posterior Stabilization in the Lower Lumbar Region.. Turkish neurosurgery. 2017. DOI: 10.5137/1019-5149.jtn.16203-15.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.