Аннотация

PURPOSE: To investigate the degree and rate of deposition of protein and lipid on FDA group II and group IV contact lens materials over a period of up to 28 days of wear.

METHODS

Twenty-two subjects wore a group IV lens (Acuvue) and a group II lens (Soflens 66) in a randomized, cross-over study. The lenses were randomly worn for periods between 1 and 28 days and then collected for laboratory-based deposition analysis.

RESULTS

The group II lenses revealed an increased degree of lipoidal spoilage (p < 0.0001) and the group IV lenses exhibited increased protein spoilage (p < 0.0001). Surface protein for both materials reached a maximum after 1 day and did not increase over the 4-week wearing period (p = NS). Total protein for group IV lenses reached a maximum between 1 and 7 days and then reached a plateau, with no further increase occurring (p = NS), whereas total protein accumulation on the group II lens continued to increase across all time periods (p < 0.05). Lipid deposition on the group IV lens was maximal after 1 day and increased no further (p = NS), whereas lipid deposition on the group II material monotonously increased and progressively built-up over the 4 weeks of wear (p < 0.0001).

CONCLUSIONS

The kinetics of contact lens deposition is mediated by the chemical structure of the contact lens material under consideration. Protein deposition occurs rapidly with group IV materials before reaching a maximum, whereas N-vinyl pyrrolidone-containing group II materials progressively accumulate protein and lipid deposits, with no plateau occurring.

Для цитирования: Jones L, Mann A, Evans K, Franklin V, Tighe B. An in vivo comparison of the kinetics of protein and lipid deposition on group II and group IV frequent-replacement contact lenses.. Optometry and vision science : official publication of the American Academy of Optometry. 2000. DOI: 10.1097/00006324-200010000-00004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.