Cementless RM Pressfit Cup: a clinical and radiological study of 91 cases with at least four years follow-up.

Lafon L, Moubarak H, Druon J, Rosset P

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

UNLABELLED: Cementless metal-back acetabular cups have good long-term results, but some problems have appeared due to the shell's stiffness, modularity and required bearing surfaces. The RM Pressfit Cup is a single-piece polyethylene cementless acetabular cup that is covered by a thin layer of titanium. This allows for bone integration without limitations related to the stiffness of a metal-back shell. There is very little published information about this new, innovative implant design. The purpose of this study was to evaluate the clinical and radiological results from a continuous series of 91 cups (85 patients) with a follow-up of at least 4 years. No patients were lost to follow-up. The Harris Hip Score (HHS) was used to assess the clinical outcome. To assess the radiological outcomes, digital X-rays were used to evaluate the cup position and integration; wear was measured using Livermore's technique. The clinical results were excellent: the mean HHS was 94 and 82% of cases had good or excellent scores. Three of the cups had to be revised because of dislocation brought on by incorrect positioning. X-rays revealed that three implants had shifted during the first 6 weeks, but had stabilized afterwards. Bone integration on X-rays was satisfactory in all cases with no signs of osteolysis. The configuration of the bone trabeculae showed that loads between the implant and peri-acetabular cancellous bone were evenly distributed. The wear of the polyethylene cup-ceramic head bearing was 0.07 mm/year. The results of this series are consistent with recent published studies with the RM Pressfit Cup.

LEVEL OF EVIDENCE: IV.

Для цитирования: Lafon L, Moubarak H, Druon J, Rosset P. Cementless RM Pressfit Cup: a clinical and radiological study of 91 cases with at least four years follow-up.. Orthopaedics & traumatology, surgery & research : OTSR. 2014. DOI: 10.1016/j.otsr.2014.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.