Аннотация
AIMS: Diabetic cheiroarthropathies limit hand mobility due to fibrosis and could be markers of a global profibrotic trajectory. Heterogeneity in definitions and lack of a method to measure it complicate studying associations with organ involvement and treatment outcomes. We measured metacarpophalangeal (MCP) joint extension as a metric and describe magnetic resonance (MR) imaging determinants of MCP restriction.
METHODS
Adults with type 1 diabetes were screened for hand manifestations using a symptom questionnaire, clinical examination, and function [Duruoz hand index (DHI) and grip strength]. Patients were segregated by mean MCP extension (<20°, 20°-40°, 40°-60°, and >60°) for MR imaging (MRI) scanning. Patients in the four groups were compared using ANOVA for clinical features and MRI tissue measurements (tenosynovial, skin, and fascia thickness). We performed multiple linear regression for determinants of MCP extension.
RESULTS
Of the 237 patients (90 men), 79 (33.8%) with cheiroarthropathy had MCP extension limitation (39° versus 61°, p < 0.01). Groups with limited MCP extension had higher DHI (1.9 vs. 0.2) but few (7%) had pain. Height, systolic blood pressure, and nephropathy were associated with mean MCP extension. Hand MRI (n = 61) showed flexor tenosynovitis in four patients and median neuritis in one patient. Groups with MCP mobility restriction had the thickest palmar skin; tendon thickness or median nerve area did not differ. Only mean palmar skin thickness was associated with MCP extension angle on multiple linear regression.
CONCLUSION
Joint mobility limitation was quantified by restricted mean MCP extension and had structural correlates on MRI. These can serve as quantitative measures for future associative and interventional studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.