MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-024-08039-z

Медицинская библиотека · BMC musculoskeletal disorders · 2024

Osteosynthesis using Scorpion plate for neer type V distal clavicle fracture.

Furuhata Ryogo, Matsumura Noboru, Kamata Yusaku, Tanji Atsushi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Neer type V distal clavicle fractures are considered the most unstable fracture type and are characterized by the disruption of continuity between the coracoclavicular (C-C) ligaments and proximal or distal bone fragments. However, owing to the rarity of such fractures, there is currently no universally accepted surgical procedure for their treatment. Recently, the scorpion plate, an anatomical, non-locking, pre-contoured plate with two grasping arms to fix the distal or inferior clavicular fragments, was introduced. This study aimed to investigate the postoperative functional and radiological outcomes of osteosynthesis using only scorpion plates in Neer type V fractures.

METHODS

We retrospectively identified 23 patients who underwent scorpion plate fixation for Neer type V fractures at two general hospitals. All patients underwent only plate fixation without C-C ligament augmentation. Subsequently, we investigated their postoperative functional outcomes, complication rates, and modified C-C distance ratio at 1 year.

RESULTS

The mean postoperative Constant score was 96 ± 5, with all cases achieving bone union. Complications within 1 year postoperatively included plate loosening in one patient (4.3%) and plate irritation in two patients (8.7%). Additionally, the modified C-C distance ratio averaged 114 ± 15%.

CONCLUSIONS

This study offers novel insights into the management of Neer type V distal clavicle fractures. Our findings indicate that osteosynthesis using only scorpion plates can lead to satisfactory functional outcomes with minimal complications.

Для цитирования: Furuhata Ryogo, Matsumura Noboru, Kamata Yusaku, Tanji Atsushi. Osteosynthesis using Scorpion plate for neer type V distal clavicle fracture.. BMC musculoskeletal disorders. 2024. DOI: 10.1186/s12891-024-08039-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.