Journal of orthopaedic case reports · 2024
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lee Anderson, Rao Brian, Yatsonsky Dave, Behrens Kyle, Stokey Phillip J, Ebraheim Nabil
Аннотация
INTRODUCTION: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra-articular distal radius fracture. Combined dorsal spanning plate and volar plating is a rare procedure reserved typically for comminuted fractures of the distal radius. This case highlights the first reported incidence in which a dorsal spanning plate of a distal radius fracture resulted in the volar displacement of the fragments, requiring subsequent volar plating. In the end, the outcome was favorable, as the follow-up imaging displayed good bone healing and union with minimal complications.
CASE REPORT: A 52-year-old male presented to the ED at our institution following a traumatic fall onto his left upper extremity. Radiographic imaging revealed fractures at the midshaft of the humerus as well as a very distal three-part intra-articular radius fracture. Due to the nature of the patient's distal radius fracture, initial fixation with a dorsal spanning plate was planned. However, follow-up imaging 3 weeks postoperatively revealed volar displacement of his fracture, so the patient underwent open reduction internal fixation with a volar distal radius plate. Follow-up over the next few months displayed a union of the fracture fragments and the dorsal spanning plate was removed 4 months postoperatively with imaging showing no complications.
CONCLUSION: We present this case to highlight the complication of volar displacement that may follow initial dorsal spanning plate fixation of a three-part intra-articular distal radius fracture that can be resolved with the addition of a volar plate, as well as possible indications for combined dorsal spanning plate and volar plate fixation of complex distal radius fractures at the time of initial fixation.
CASE REPORT: A 52-year-old male presented to the ED at our institution following a traumatic fall onto his left upper extremity. Radiographic imaging revealed fractures at the midshaft of the humerus as well as a very distal three-part intra-articular radius fracture. Due to the nature of the patient's distal radius fracture, initial fixation with a dorsal spanning plate was planned. However, follow-up imaging 3 weeks postoperatively revealed volar displacement of his fracture, so the patient underwent open reduction internal fixation with a volar distal radius plate. Follow-up over the next few months displayed a union of the fracture fragments and the dorsal spanning plate was removed 4 months postoperatively with imaging showing no complications.
CONCLUSION: We present this case to highlight the complication of volar displacement that may follow initial dorsal spanning plate fixation of a three-part intra-articular distal radius fracture that can be resolved with the addition of a volar plate, as well as possible indications for combined dorsal spanning plate and volar plate fixation of complex distal radius fractures at the time of initial fixation.