Automatic analysis of global spinal alignment from simple annotation of vertebral bodies.
Аннотация
Purpose: Measurement of global spinal alignment (GSA) is an important aspect of diagnosis and treatment evaluation for spinal deformity but is subject to a high level of inter-reader variability. Approach: Two methods for automatic GSA measurement are proposed to mitigate such variability and reduce the burden of manual measurements. Both approaches use vertebral labels in spine computed tomography (CT) as input: the first (EndSeg) segments vertebral endplates using input labels as seed points; and the second (SpNorm) computes a two-dimensional curvilinear fit to the input labels. Studies were performed to characterize the performance of EndSeg and SpNorm in comparison to manual GSA measurement by five clinicians, including measurements of proximal thoracic kyphosis, main thoracic kyphosis, and lumbar lordosis.
Results
For the automatic methods, 93.8% of endplate angle estimates were within the inter-reader 95% confidence interval ( CI 95 ). All GSA measurements for the automatic methods were within the inter-reader CI 95 , and there was no statistically significant difference between automatic and manual methods. The SpNorm method appears particularly robust as it operates without segmentation.
Conclusions
Such methods could improve the reproducibility and reliability of GSA measurements and are potentially suitable to applications in large datasets-e.g., for outcome assessment in surgical data science.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.