MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.118847

Медицинская библиотека · Biosensors & bioelectronics · 2026

Mycobacterium tuberculosis urine ESAT-6 antigen homogeneous immunoassay through spatial confinement and cascade material amplification.

Jiang Pengjun, Xiong Ying, Hu Hanjia, Jin Yaxiong, Peng Wu, Chen Piaopiao

СтатьяПеревод в очереди

Аннотация

Tuberculosis (TB) remains one of the leading causes of death from infectious diseases. Early secreted antigenic target-6 (ESAT-6) is a specific biomarker for active Mycobacterium TB infection; however, its ultrasensitive detection in urine specimens remains challenging. Herein, a homogeneous immunoassay for ESAT-6 detection integrating spatial confinement-mediated DNA conformational switching with cascade signal amplification is reported. The system employs antibody-bound triplet DNA molecules stabilized by C-Ag+-C coordination; specific antigen binding induces conformational changes that disrupt complexes, releasing Ag+ that initiates a cation exchange reaction (CER) with CuS nanoparticles (NPs) to generate Cu2+, and potently quenches CdTe quantum dots (QDs) with a secondary CER. This homogeneous platform operates without washing steps or enzyme-based amplification, achieving a limit of detection of 30 ag/mL with a linear range of 0.1-100 fg/mL. Clinical validation using 80 urine specimens (40 TB-positive and 40 negative) demonstrated highly significant discrimination between groups (p < 0.001), with receiver operating characteristic analysis confirming robust diagnostic performance. ESAT-6 testing exhibited excellent concordance with imaging findings and correlated strongly with enzyme-linked immunosorbent assay measurements. This system provides a one-pot urine-based detection tool for rapid TB diagnosis, significantly reducing operational complexity to meet clinical demands.

Для цитирования: Jiang Pengjun, Xiong Ying, Hu Hanjia, Jin Yaxiong, Peng Wu, Chen Piaopiao. Mycobacterium tuberculosis urine ESAT-6 antigen homogeneous immunoassay through spatial confinement and cascade material amplification.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.118847.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.