MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/ar3854

Медицинская библиотека · Arthritis research & therapy · 2012

Can erosions on MRI of the sacroiliac joints be reliably detected in patients with ankylosing spondylitis? - A cross-sectional study.

Weber Ulrich, Pedersen Susanne J, Østergaard Mikkel, Rufibach Kaspar, Lambert Robert G W, Maksymowych Walter P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Erosions of the sacroiliac joints (SIJ) on pelvic radiographs of patients with ankylosing spondylitis (AS) are an important feature of the modified New York classification criteria. However, radiographic SIJ erosions are often difficult to identify. Recent studies have shown that erosions can be detected also on magnetic resonance imaging (MRI) of the SIJ early in the disease course before they can be seen on radiography. The goals of this study were to assess the reproducibility of erosion and related features, namely, extended erosion (EE) and backfill (BF) of excavated erosion, in the SIJ using a standardized MRI methodology.

METHODS

Four readers independently assessed T1-weighted and short tau inversion recovery sequence (STIR) images of the SIJ from 30 AS patients and 30 controls (15 patients with non-specific back pain and 15 healthy volunteers) ≤ 45 years old. Erosions, EE, and BF were recorded according to standardized definitions. Reproducibility was assessed by percentage concordance among six possible reader pairs, kappa statistics (erosion as binary variable) and intraclass correlation coefficient (ICC) (erosion as sum score) for all readers jointly.

RESULTS

SIJ erosions were detected in all AS patients and six controls by ≥ 2 readers. The median number of SIJ quadrants affected by erosion recorded by four readers in 30 AS patients was 8.6 in the iliac and 2.1 in the sacral joint portion (P < 0.0001). For all 60 subjects and for all four readers, the kappa value for erosion was 0.72, 0.73 for EE, and 0.63 for BF. ICC for erosion was 0.79, 0.72 for EE, and 0.55 for BF, respectively. For comparison, the kappa and ICC values for bone marrow edema were 0.61 and 0.93, respectively.

CONCLUSIONS

Erosions can be detected on MRI to a comparable degree of reliability as bone marrow edema despite the significant heterogeneity of their appearance on MRI.

Для цитирования: Weber Ulrich, Pedersen Susanne J, Østergaard Mikkel, Rufibach Kaspar, Lambert Robert G W, Maksymowych Walter P. Can erosions on MRI of the sacroiliac joints be reliably detected in patients with ankylosing spondylitis? - A cross-sectional study.. Arthritis research & therapy. 2012. DOI: 10.1186/ar3854.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.