MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2016.02.021

Медицинская библиотека · The Knee · 2016

Favorable femoral component rotation achieved in severe varus deformity by using the gap-balancing technique.

Gao Yu-Hang, Li Shu-Qiang, Yang Chen, Liu Jian-Guo, Dong Ning, Qi Xin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In a group of patients with severe varus deformity, this study used the gap-balancing technique and evaluated component rotation by using postoperative CT scans in order to determine whether a favorable axis could be achieved.

METHODS

Thirty-one patients (34 knees) with varus deformity of >15°, and 31 age-matched and sex-matched patients (36 knees) with varus deformity of ≤15° were enrolled. The transepicondylar axis and three degrees of external rotation off the posterior femoral condylar axis were lined out intraoperatively to compare measurements relative to the gap-balancing axis. Joint line elevations were determined, and the femoral component rotation was evaluated on postoperative CT scans.

RESULTS

Most of the study patients required stripping the capsule off the posteromedial distal femur and release of the medial collateral ligament. The difference in tibial joint line elevation was not significantly different (P=0.134). The two groups did not differ significantly in terms of the transepicondylar axis relative to the gap-balancing axis (P=0.166), the three degrees of external rotation off the posterior femoral condylar axis relative to the gap-balancing axis (P=0.913), the posterior condylar angles (P=0.218), and the prevalence of cases with a variation of ≤±3° in all alignment measurements. Comparable clinical outcomes were determined.

CONCLUSIONS

When the gap-balancing technique was used in the patients with severe varus deformity of >15°, over-release of the medial collateral ligament was avoided when tight posteromedial structures had been corrected first, and favorable femoral component rotations were achieved.

Для цитирования: Gao Yu-Hang, Li Shu-Qiang, Yang Chen, Liu Jian-Guo, Dong Ning, Qi Xin. Favorable femoral component rotation achieved in severe varus deformity by using the gap-balancing technique.. The Knee. 2016. DOI: 10.1016/j.knee.2016.02.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.