Cytometry. Part A : the journal of the International Society for Analytical Cytology · 2021
Upconversion nanoparticle-assisted single-molecule assay for detecting circulating antigens of aggressive prostate cancer.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chen Yinghui, Shimoni Olga, Huang Guan, Wen Shihui, Liao Jiayan, Duong Hien T T, Maddahfar Mahnaz, Su Qian Peter, Ortega David Gallego, Lu Yanling, Campbell Douglas H, Walsh Bradley J, Jin Dayong
Аннотация
Sensitive and quantitative detection of molecular biomarkers is crucial for the early diagnosis of diseases like metabolic syndrome and cancer. Here we present a single-molecule sandwich immunoassay by imaging the number of single nanoparticles to diagnose aggressive prostate cancer. Our assay employed the photo-stable upconversion nanoparticles (UCNPs) as labels to detect the four types of circulating antigens in blood circulation, including glypican-1 (GPC-1), leptin, osteopontin (OPN), and vascular endothelial growth factor (VEGF), as their serum concentrations indicate aggressive prostate cancer. Under a wide-field microscope, a single UCNP doped with thousands of lanthanide ions can emit sufficiently bright anti-Stokes' luminescence to become quantitatively detectable. By counting every single streptavidin-functionalized UCNP which specifically labeled on each sandwich immune complex across multiple fields of views, we achieved the Limit of Detection (LOD) of 0.0123 ng/ml, 0.2711 ng/ml, 0.1238 ng/ml, and 0.0158 ng/ml for GPC-1, leptin, OPN and VEGF, respectively. The serum circulating level of GPC-1, leptin, OPN, and VEGF in a mixture of 10 healthy normal human serum was 25.17 ng/ml, 18.04 ng/ml, 11.34 ng/ml, and 1.55 ng/ml, which was within the assay dynamic detection range for each analyte. Moreover, a 20% increase of GPC-1 and OPN was observed by spiking the normal human serum with recombinant antigens to confirm the accuracy of the assay. We observed no cross-reactivity among the four biomarker analytes, which eliminates the false positives and enhances the detection accuracy. The developed single upconversion nanoparticle-assisted single-molecule assay suggests its potential in clinical usage for prostate cancer detection by monitoring tiny concentration differences in a panel of serum biomarkers.