DOI 10.1016/j.dental.2025.02.007
Bond strength of a 3-step total-etch bonding system to dentine - An improved approach.
Аннотация
BACKGROUND
Generally, the bonding of one material to another is important for function, and especially in so-called 'adhesive dentistry'. However, there are concerns about the clinical relevance and the discriminatory power of currently employed tests of bond strength.
OBJECTIVE
Develop and validate a test protocol based on 4-point bending that may be used to examine the bonding of various dental materials to a range of substrates. The bonding of a resin-based composite (RBC) to dentine is taken as an example.
METHODS
Slices of dentine 'coupons' (5.0 × 2.0 × ∼4-6 mm3) from extracted molars were prepared using a diamond saw under running water. Pairs of RBC bars (5.0 × 2.0 × ∼24 mm3) (Z250) were bonded symmetrically either side of a dentine coupon using all combinations of the following treatments: E: acid-etched (Scotchbond Universal Etchant), P: primer (Adper Scotchbond Multipurpose Adhesive); A: adhesive (Adper Scotchbond Multipurpose Primer) (all 3 M) as well as N: no treatment. Following retrieval from the mould, test pieces were immediately subjected to 4-point bending at 23 °C, cross-head speed 0.5 mm/min, until fracture. Three-way analysis of variance on log(flexural strength): etch × primer × adhesive, was applied. Scanning electron microscopy (SEM) was used to examine fracture surfaces and identify failure origins.
RESULTS
Flexural strengths in MPa: N: 1.38 ± 0.56; P: 9.82 ± 0.89; A: 5.12 ± 0.73; E: 9.39 ± 1.78; E + P: 21.03 ± 2.63; E + A: 12.80 ± 1.53; P + A: 17.16 ± 3.03; E + P + A: 20.84 ± 3.93. The treatment main effects (all, p < 10-12) were not additive, there being significant two-way (p < 10-5) and three-way (p = 0.037) interactions. There was no significant difference between E + P + A and E + P (p = 0.86).
CONCLUSION
With good reproducibility (low scatter), discriminatory power (clear treatment effects), economy with regard to substrates, the method has the potential to be adaptable to many systems.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.