Prediction of myelopathic level in cervical spondylotic myelopathy using diffusion tensor imaging.
Аннотация
PURPOSE: To investigate the use of a newly designed machine learning-based classifier in the automatic identification of myelopathic levels in cervical spondylotic myelopathy (CSM).
MATERIALS AND
METHODS
In all, 58 normal volunteers and 16 subjects with CSM were recruited for diffusion tensor imaging (DTI) acquisition. The eigenvalues were extracted as the selected features from DTI images. Three classifiers, naive Bayesian, support vector machine, and support tensor machine, and fractional anisotropy (FA) were employed to identify myelopathic levels. The results were compared with clinical level diagnosis results and accuracy, sensitivity, and specificity were calculated to evaluate the performance of the developed classifiers.
RESULTS
The accuracy by support tensor machine was the highest (93.62%) among the three classifiers. The support tensor machine also showed excellent capacity to identify true positives (sensitivity: 84.62%) and true negatives (specificity: 97.06%). The accuracy by FA value was the lowest (76%) in all the methods.
CONCLUSION
The classifiers-based method using eigenvalues had a better performance in identifying the levels of CSM than the diagnosis using FA values. The support tensor machine was the best among three classifiers.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.