MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjps.2025.04.047

Медицинская библиотека · Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2025

Combined latissimus dorsi myocutaneous flap and 3D-printed PEEK implant for reconstruction of a large full-thickness chest wall defect: A retrospective study.

Huo Jun-Yi, Li Yu-Qian, Zhao Cong-Ying, Zhao Zhuo-Wei, Du Jin-Cheng, Wang Lei, Yang San-Hu, Duan Ce-Zhong, Zhao Yuan, Huang Li-Jun, Li Jing

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Reconstruction of extensive full-thickness chest wall defects is a noticed challenge within the field. Although 3D-printed polyether ether ketone (PEEK) has exhibited promising outcomes in cranial and maxillary reconstruction, its application combined with flap in reconstruction of a full-thickness chest wall defects remains unexplored.

METHODS

Over the span from November 2018 to March 2024, a retrospective study involving 12 patients who underwent chest wall reconstruction using latissimus dorsi myocutaneous flap (LDMF) combined with 3D-printed PEEK prostheses after tumor resections at our institution was meticulously conducted. Comprehensive clinical data, encompassing patient demographics, tumor characteristics, surgical details, postoperative complications, and long-term functional outcomes, were methodically collected, analyzed, and synthesized.

RESULTS

Among the cohort of 12 patients, 11 experienced successful primary wound healing, whereas a single case necessitated secondary intervention involving debridement and suturing because of necrosis at the distal end of the flap. The follow-up duration ranged from 3 to 54 months. The PEEK prosthesis demonstrated excellent stability, structural support, and integration with surrounding tissues. All the LDMFs exhibited well-defined contours and compatibility with the implants. Functional assessments including mobility of the repaired thoracic wall, respiratory function, shoulder joint movement, pain, cosmetic appearance, and quality of life yielded consistently satisfactory results.

CONCLUSION

The combined utilization of LDMF with 3D-printed PEEK prostheses offers a tailored and resilient approach for comprehensive full-thickness chest wall reconstruction postextensive tumor resection. This method achieves satisfactory functional outcomes with minimal postoperative complications, contributing to prolonged survival and enhanced quality of life.

Для цитирования: Huo Jun-Yi, Li Yu-Qian, Zhao Cong-Ying, Zhao Zhuo-Wei, Du Jin-Cheng, Wang Lei, Yang San-Hu, Duan Ce-Zhong, Zhao Yuan, Huang Li-Jun, Li Jing. Combined latissimus dorsi myocutaneous flap and 3D-printed PEEK implant for reconstruction of a large full-thickness chest wall defect: A retrospective study.. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. 2025. DOI: 10.1016/j.bjps.2025.04.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.