MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/hep.32134

Медицинская библиотека · Hepatology (Baltimore, Md.) · 2021

Quantification of polyreactive immunoglobulin G facilitates the diagnosis of autoimmune hepatitis.

Taubert Richard, Engel Bastian, Diestelhorst Jana, Hupa-Breier Katharina L, Behrendt Patrick, Baerlecken Niklas T, Sühs Kurt-Wolfram, Janik Maciej K, Zachou Kalliopi, Sebode Marcial, Schramm Christoph, Londoño María-Carlota, Habes Sarah, UK-AIH Consortium, Oo Ye H, Lalanne Claudine, Pape Simon, Schubert Maren, Hust Michael, Dübel Stefan, Thevis Mario, Jonigk Danny, Beimdiek Julia, Buettner Falk F R, Drenth Joost P H, Muratori Luigi, Adams David H, Dyson Jessica K, Renand Amédée, Graupera Isabel, Lohse Ansgar W, Dalekos George N, Milkiewicz Piotr, Stangel Martin, Maasoumy Benjamin, Witte Torsten, Wedemeyer Heiner, Manns Michael P, Jaeckel Elmar

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Detection of autoantibodies is a mainstay of diagnosing autoimmune hepatitis (AIH). However, conventional autoantibodies for the workup of AIH lack either sensitivity or specificity, leading to substantial diagnostic uncertainty. We aimed to identify more accurate serological markers of AIH with a protein macroarray.

APPROACH AND

RESULTS

During the search for more-precise autoantibodies to distinguish AIH from non-AIH liver diseases (non-AIH-LD), IgG antibodies with binding capacities to many human and foreign proteins were identified with a protein macroarray and confirmed with solid-phase ELISAs in AIH patients. Subsequently, polyreactive IgG (pIgG) was exemplarily quantified by reactivity against human huntingtin-interacting protein 1-related protein in bovine serum albumin blocked ELISA (HIP1R/BSA). The diagnostic fidelity of HIP1R/BSA binding pIgG to diagnose AIH was assessed in a retrospective training, a retrospective multicenter validation, and a prospective validation cohort in cryoconserved samples from 1,568 adults from 10 centers from eight countries. Reactivity against HIP1R/BSA had a 25% and 14% higher specificity to diagnose AIH than conventional antinuclear and antismooth muscle antibodies, a significantly higher sensitivity than liver kidney microsomal antibodies and antisoluble liver antigen/liver pancreas antigen, and a 12%-20% higher accuracy than conventional autoantibodies. Importantly, HIP1R/BSA reactivity was present in up to 88% of patients with seronegative AIH and in up to 71% of AIH patients with normal IgG levels. Under therapy, pIgG returns to background levels of non-AIH-LD.

CONCLUSIONS

pIgG could be used as a promising marker to improve the diagnostic workup of liver diseases with a higher specificity for AIH compared to conventional autoantibodies and a utility in autoantibody-negative AIH. Likewise, pIgG could be a major source of assay interference in untreated AIH.

Для цитирования: Taubert Richard, Engel Bastian, Diestelhorst Jana, Hupa-Breier Katharina L, Behrendt Patrick, Baerlecken Niklas T, Sühs Kurt-Wolfram, Janik Maciej K, Zachou Kalliopi, Sebode Marcial, Schramm Christoph, Londoño María-Carlota, Habes Sarah, UK-AIH Consortium, Oo Ye H, Lalanne Claudine, Pape Simon, Schubert Maren, Hust Michael, Dübel Stefan, Thevis Mario, Jonigk Danny, Beimdiek Julia, Buettner Falk F R, Drenth Joost P H, Muratori Luigi, Adams David H, Dyson Jessica K, Renand Amédée, Graupera Isabel, Lohse Ansgar W, Dalekos George N, Milkiewicz Piotr, Stangel Martin, Maasoumy Benjamin, Witte Torsten, Wedemeyer Heiner, Manns Michael P, Jaeckel Elmar. Quantification of polyreactive immunoglobulin G facilitates the diagnosis of autoimmune hepatitis.. Hepatology (Baltimore, Md.). 2021. DOI: 10.1002/hep.32134.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.