[Acetabular reconstruction in revision arthroplasty. Retrospective study of 76 cases. Hospital Español de México].
Аннотация
OBJECTIVE
To review our experience with the various acetabular reconstruction techniques used during revision arthroplasty based on the defect in each patient.
MATERIAL AND
METHODS
We undertook a retrospective, descriptive, observational study of patients who underwent acetabular reconstruction during revision ar. throplasty, from January 1997 to January 2005. We documented the type of acetabular defect, the type of cup and graft used, the complications, and the pre- and postoperative assessment with the Harris scale. Data were analyzed with the SPSS software and the Wilcoxon test (p < 0.05).
RESULTS
Seventy-six patients underwent surgery. Mean time elapsed between the primary replacement and the revision was 5 years. The acetabular defects found were: 16 type I, 22 type II, 30 type IIIA, and 8 type IIIB. The mean Harris score was 44 preoperatively and 76 postoperatively. The most frequently used technique involved the use of an autograft, a structural allograft with a porous threaded cup or a reinforcement ring. The most common complications included dislocation 5%, infection 3%, graft loss and cup loosening 21%, and loss of the hip center of rotation 15% (p < 0.05).
CONCLUSIONS
Acetabular reconstruction is technically challenging and involves high failure and complication rates, thus providing little improvement in patient activity. It is important to restore the hip center of rotation to improve function. The reconstruction techniques we used are the most common ones and are described in the literature.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.