The Journal of thoracic and cardiovascular surgery · 2023

Transapical ventricular reshaping reduces functional mitral regurgitation and improves ventricular function in a preclinical model of ischemic cardiomyopathy.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

King Chase L, Onohara Daisuke, Tom Stephanie K, Silverman Michael, Kikuchi Yuta, Lane Brooks A, Wong Keawepono, Toma Julia R, Maddamma Amanda, Padala Muralidhar

Аннотация

OBJECTIVE: A significant proportion of patients with advanced heart failure present with dilated left ventricles and functional mitral regurgitation. These patients currently have limited treatment options. The MitraClip device (Abbott) has benefited only patients with smaller left ventricles (end-diastolic dimension <70 mm), whereas those with larger left ventricles did not benefit. A possible explanation is correcting functional mitral regurgitation alone may not adequately reduce the wall stresses of a dilated left ventricle. We have developed a beating-heart device that not only approximates the papillary muscles to reduce functional mitral regurgitation but also modifies the left ventricle size and shape to reduce wall stress.

METHODS: Yorkshire swine (n = 16) had a myocardial infarction induced by permanent occlusion of the left circumflex with intracoronary ethanol. Three months later, the animals developed heart failure and moderate or greater functional mitral regurgitation. Through a transapical approach, the new device was implanted under echocardiography guidance to reshape the left ventricle and correct functional mitral regurgitation. The acute impact of this approach on the mitral valve and left ventricle was assessed with echocardiography and invasive hemodynamics.

RESULTS: After reshaping, echocardiography showed a decrease in end-diastolic volume by 36.3 ± 30.5 mL (P < .001), a decrease in sphericity index by 0.143 ± 0.087 (P < .001), and an increase in ejection fraction of 5.90% ± 6.38% (P < .01). Mitral valve tenting area was reduced by 39.29 ± 33.66 mm2 (P < .001), coaptation length was increased by 2.12 ± 1.02 mm (P < .001), and posterior excursion angle was improved by 9.07° ± 9.14° (P < .01), resulting in functional mitral regurgitation reduction.

CONCLUSIONS: Correction of functional mitral regurgitation with favorable changes in mitral valve geometry and reduction in left ventricle geometry is possible with the proposed device.