MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-026-04071-3

Медицинская библиотека · Annals of biomedical engineering · 2026

In Vivo Assessment of SED: A Novel Biomechanical Indicator for Periodontal Tissue Remodeling in Clear Aligner Therapy.

Liu Xulin, Zhang Mingxin, Fan Xinyue, Luo Houzhuo, Wang Axian, Zhang Xu, Qin Yuan, Zhang Xiaochen, Jin Zuolin, Ma Yanning

СтатьяПеревод в очереди

Аннотация

PURPOSE: Orthodontic tooth movement fundamentally relies on force-driven remodeling of periodontal tissues. However, the therapeutic predictability of clear aligner therapy (CAT) remains limited, particularly in periodontal-compromised patients. This limitation stems from a critical gap between biomechanical loading and biological remodeling. This study innovatively adopts strain energy density (SED) as a biomechanical parameter to investigate the integrated biomechanical and biological responses of the periodontium to CAT.

METHODS

We employed a cross-scale biomimetic framework that combined three-dimensional finite element modeling (FEM) with an in vivo rabbit model. Biological assays, including micro-CT, TRAP staining, immunohistochemistry, 4D proteomics, the Oroboros Oxygraph-2000 (O2K), and Western blot (WB), were conducted in SED-concentrated areas to elucidate SED-triggered biological cascades.

RESULTS

FEM quantified that periodontal SED escalated with attachment loss, concentrating at the labial alveolar crest. In vivo experiments indicated that elevated SED exacerbated periodontal damage, evidenced by reduced bone volume fraction and density, increased TRAP-positive osteoclasts, upregulated IL-1β, and downregulated BMP2. Proteomics identified 908 differential proteins in high-SED regions, which are enriched in NF-κB activation and suppression of oxidative phosphorylation. O2K and WB validated compromised mitochondrial complex I/II function, ATP production, and phosphate/oxygen ratio in these areas.

CONCLUSION

Using SED as a quantitative metric, this study bridges the biomechanical-biological gap by linking CAT-induced biomechanical responses to mitochondrial bioenergetic dysfunction. These findings establish a basis for a biologically informed predictive system to facilitate personalized CAT.

Для цитирования: Liu Xulin, Zhang Mingxin, Fan Xinyue, Luo Houzhuo, Wang Axian, Zhang Xu, Qin Yuan, Zhang Xiaochen, Jin Zuolin, Ma Yanning. In Vivo Assessment of SED: A Novel Biomechanical Indicator for Periodontal Tissue Remodeling in Clear Aligner Therapy.. Annals of biomedical engineering. 2026. DOI: 10.1007/s10439-026-04071-3.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.