MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcot.2019.04.010

Медицинская библиотека · Journal of clinical orthopaedics and trauma · 2019

Severe metallosis-related osteolysis as a cause of failure after total knee replacement.

Salem Khaled Hamed, Lindner Norbert, Tingart Markus, Elmoghazy Alyaa Diaa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Metallosis is a syndrome of metal-induced synovitis caused by friction between two metal surfaces. In contrast to the hip joint after resurfacing arthroplasty or metal-on-metal (MoM) total hip replacement, metallosis of the knee is extremely rare.

MATERIALS: We describe 4 patients who underwent revision total knee replacement because of disabling pain and implant loosening after a mean time of 21 (range: 13-30) years of knee replacement surgery. They were all females with a mean age of 79 (range: 75-82) years. Septic loosening was excluded through microbiological examination and synovial fluid analysis.

RESULTS

Direct metal-on-metal contact at the tibiofemoral interface was confirmed intraoperatively in all cases. All knees showed severe metallosis with advanced osteolysis and pseudotumor formation. In one knee there was a complete fracture of the tibial tray. All patients had a one-stage revision surgery with implant removal, profound synovectomy and implantation of a constrained modular revision knee system. Long modular stems with offset adapters, wedges and/or blocks were used in all cases.

CONCLUSION

Metallosis-associated osteolysis should be suspected in cases with radiologically evident polyethylene wear after knee replacement. Recognizing that revision arthroplasty is very technically demanding in such cases, surgeons should have a back-up with modular revision components and a ready access to reconstructive options at this revision setting.

Для цитирования: Salem Khaled Hamed, Lindner Norbert, Tingart Markus, Elmoghazy Alyaa Diaa. Severe metallosis-related osteolysis as a cause of failure after total knee replacement.. Journal of clinical orthopaedics and trauma. 2019. DOI: 10.1016/j.jcot.2019.04.010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.