MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13075-022-02835-5

Медицинская библиотека · Arthritis research & therapy · 2022

Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis.

Mukherjee Monica, Mercurio Valentina, Balasubramanian Aparna, Shah Ami A, Hsu Steven, Simpson Catherine E, Damico Rachel, Kolb Todd M, Hassoun Paul M, Mathai Stephen C

СтатьяПоддержка правительства СШАПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Echocardiography (2DE) is integral for screening and longitudinal evaluation of pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc). In the present study, we sought to establish the reliability, repeatability, and reproducibility of 2DE parameters in SSc patients with and without PAH and to define the minimal detectable difference (MDD), the smallest change detected beyond measurement error.

METHODS

SSc patients without known PAH and with invasively confirmed PAH on stable therapies underwent 2DE with strain at two time points. Analysis of variance (ANOVA) and coefficients of variation (CV) were calculated to assess for repeatability, reliability, and reproducibility. Intra- and inter-observer agreement were assessed using intraclass correlation. Bland-Altman analysis explored the level of agreement between evaluations. MDD was calculated using the standard error of measurement for each parameter by cohort.

RESULTS

ANOVA demonstrated few significant differences between evaluations across groups. Global right ventricular longitudinal systolic strain (GRVLSS, 9.7%) and fractional area change (FAC, 21.3%) had the largest CV, while tricuspid annular plane excursion (TAPSE), S' wave, and right ventricular outflow track velocity time integral (RVOT VTI) were 0.87%, 3.2%, and 6.0%, respectively. Intra- and inter-observer agreement was excellent. MDD for TAPSE, FAC, S' wave, RVOT VTI, GRVLSS, and RVSP were 0.11 cm, 0.03%, 1.27 cm/s, 0.81 cm, 1.14%, and 6.5 mmHg, respectively.

CONCLUSIONS

We demonstrate minimal measurement error in clinically important 2DE-based measures in SSc patients with and without PAH. Defining the MDD in this population has important implications for PAH screening, assessment of therapeutic response, and sample size calculations for future clinical trials.

Для цитирования: Mukherjee Monica, Mercurio Valentina, Balasubramanian Aparna, Shah Ami A, Hsu Steven, Simpson Catherine E, Damico Rachel, Kolb Todd M, Hassoun Paul M, Mathai Stephen C. Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis.. Arthritis research & therapy. 2022. DOI: 10.1186/s13075-022-02835-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.