MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jos.2017.10.004

Медицинская библиотека · Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2017

Predicting pathological fracture in femoral metastases using a clinical CT scan based algorithm: A case-control study.

Janssen Stein J, Paulino Pereira Nuno Rui, Meijs Timion A, Bredella Miriam A, Ferrone Marco L, van Dijk C Niek, Bramer Jos A M, Lozano-Calderón Santiago A, Schwab Joseph H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We assessed whether there was a difference in attenuation measurements (in Hounsfield units - HU) and geometric distribution of HU between femora with metastatic lesions that fracture, and metastatic lesions that did not fracture nor underwent prophylactic fixation.

METHODS

Nine patients with femoral metastases who underwent CT and developed a pathological fracture were matched to controls. All femora were delineated in axial CT slices using a region of interest (ROI) tool; the HU within these ROIs were used to calculate: (1) the cumulative HU of the affected over the nonaffected side per slice and presented as a percentage, and (2) the cumulative HU accounting for geometric distribution (polar moment of HU). We repeated the analyses including cortical bone only (HU of 600 and above).

RESULTS

CT-based calculations did not differ between patients with a lesion that fractured and those that did not fracture nor underwent prophylactic fixation when analyzing all tissue. However, when including cortical bone only, the pathological fracture group had a lower cumulative HU value compared to the no fracture and no fixation group for the weakest cross-sectional CT image (pathological fracture group, mean: 71, SD: 23 and no fracture and no prophylactic fixation group, mean: 85, SD: 18, p = 0.042) and the complete lesion analysis (pathological fracture group, mean: 78, SD: 21 and no fracture and no prophylactic fixation group, mean: 92, SD: 15, p = 0.032).

CONCLUSION

The demonstrated CT-based algorithms can be useful for predicting pathological fractures in metastatic lesions.

Для цитирования: Janssen Stein J, Paulino Pereira Nuno Rui, Meijs Timion A, Bredella Miriam A, Ferrone Marco L, van Dijk C Niek, Bramer Jos A M, Lozano-Calderón Santiago A, Schwab Joseph H. Predicting pathological fracture in femoral metastases using a clinical CT scan based algorithm: A case-control study.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2017. DOI: 10.1016/j.jos.2017.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.