MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2016.57.1.225

Медицинская библиотека · Yonsei medical journal · 2016

Radiologic Outcomes According to Varus Deformity in Minimally Invasive Surgery Total Knee Arthroplasty.

Yoo Ju Hyung, Park Sang Hoon, Han Chang Dong, Oh Hyun Cheol, Park Jun Young, Choi Seung Jin

СтатьяПеревод в очереди

Аннотация

PURPOSE: To identify the accuracy of postoperative implant alignment in minimally invasive surgery total knee arthroplasty (MIS-TKA), based on the degree of varus deformity.

MATERIALS AND

METHODS

The research examined 627 cases of MIS-TKA from November 2005 to December 2007. The cases were categorized according to the preoperative degree of varus deformity in the knee joint in order to compare the postoperative alignment of the implant: less than 5° varus (Group 1, 351 cases), 5° to less than 10° varus (Group 2, 189 cases), 10° to less than 15° varus (Group 3, 59 cases), and 15° varus or more (Group 4, 28 cases).

RESULTS

On average, the alignment of the tibial implant was 0.2±1.4°, 0.1±1.3°, 0.1±1.6°, and 0.3±1.7° varus, and the tibiofemoral alignment was 5.2±1.9degrees, 4.7±1.9°, 4.9±1.9°, and 5.1±2.0° valgus for Groups 1, 2, 3, and 4, respectively, in the preoperative stage, indicating no difference between the groups (p>0.05). With respect to the accuracy of the tibial implant alignment, 98.1%, 97.6%, 87.5%, and 86.7% of Groups 1, 2, 3, and 4, respectively, had 0±3° varus angulation, demonstrating a reduced level of accuracy in Groups 3 and 4 (p<0.0001). There was no difference in terms of tibiofemoral alignment, with 83.9%, 82.9%, 85.4%, and 86.7% of each group, respectively, showing 6±3° valgus angulation (p>0.05).

CONCLUSION

Satisfactory component alignment was achieved in minimally invasive surgery in total knee arthroplasty, regardless of the degree of varus deformity.

Для цитирования: Yoo Ju Hyung, Park Sang Hoon, Han Chang Dong, Oh Hyun Cheol, Park Jun Young, Choi Seung Jin. Radiologic Outcomes According to Varus Deformity in Minimally Invasive Surgery Total Knee Arthroplasty.. Yonsei medical journal. 2016. DOI: 10.3349/ymj.2016.57.1.225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.