MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/jmdh.s392058

Медицинская библиотека · Journal of multidisciplinary healthcare · 2022

Responsiveness of the Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy.

Phyu Sitt Nyein, Wanpen Sawitri, Chatchawan Uraiwan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Mini-BESTest is an instrument for assessing the balance impairment; however, the use of the Mini-BESTest in type 2 diabetic patients with peripheral neuropathy is not well documented in the literature. The aim of this study was to examine the responsiveness and the minimal important change (MIC) of the Mini-BESTest after four weeks of the balance exercises.

METHODS

A prospective single group pretest-posttest design was applied, and forty-eight type 2 diabetic patients with peripheral neuropathy were participated (mean age of 59.04 ± 7.533 years; 3 males and 45 females). All participants were given an intervention program including foot care and balance exercises (50-minute sessions, three times a week for four weeks). The responsiveness of the Mini-BESTest was determined using two approaches: 1) the distribution-based method evaluating the change scores (pre- and post-intervention), the effect size (ES), the standard response mean (SRM), the standard error of measurement (SEM) and the minimum detectable change (MDC95) and 2) the anchor-based method evaluating the MIC using the Global Rating of Change scale (GRC) as an external criterion.

RESULTS

After the balance exercises treatment, the Mini-BESTest scores significantly improved (p < 0.001) with an ES of 3.9 and SRM of 4.32. SEM was 0.73 and MDC95 was 2.03 points. The area under the receiver operating characteristic (ROC) curve corresponded to 81%. The cutoff point of the Mini-BESTest was ≥5 points corresponding to the GRC ≤3 versus >3 for the discrimination of the Mini-BESTest between improvement and no improvement after exercises.

CONCLUSION

The Mini-BESTest can be demonstrated as high responsiveness according to the determination of the distribution-based and the anchor-based methods. The MIC of the Mini-BESTest was taken as ≥5 points and could be used as an outcome measure for the discriminated evaluation of type 2 diabetic patients with peripheral neuropathy.

Для цитирования: Phyu Sitt Nyein, Wanpen Sawitri, Chatchawan Uraiwan. Responsiveness of the Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy.. Journal of multidisciplinary healthcare. 2022. DOI: 10.2147/jmdh.s392058.