MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.14635

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2018

Wrist and Hand Ultrasound: Reliability of Side-to-Side Comparisons of Very Small (<2-mm) Clinically Relevant Anatomic Structures.

Rossi Federica, Romano Nicola, Muda Alessandro, Martinoli Carlo, Tagliafico Alberto

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

In ultrasound (US) examinations of clinically relevant very small structures of the wrist and hand, the healthy contralateral side can be used as a reference to identify subtle abnormalities. Intraindividual side-to-side variability must be minimal. The aim of this study was to assess the reliability of side-to-side US evaluations of very small structures of the wrist and hand.

METHODS

Forty-one healthy volunteers were prospectively studied. Small structures of the wrist and hand were evaluated bilaterally by 2 musculoskeletal radiologists in separate sessions. The first annular pulleys of the second finger and the thumb, sagittal band of the third finger, extensor and flexor retinacula, ulnar collateral ligament of the thumb, radial collateral ligament of the second finger, and palmar cutaneous branches of the median and ulnar nerves were considered. To assess intra- and inter-reader agreement, 10 of 41 (24%) examinations were repeated. Nonparametric statistics were used.

RESULTS

Data were not normally distributed (P > .001). Intra-reader agreement was κ = 0.674 (95% confidence interval [CI], 0.57-0.78), and inter-reader agreement was κ = 0.935 (95% CI, 0.92-0.95). The mean value ± SD for all of the structures was 0.78 ± 0.44 mm. The overall coefficient of variation was 9.8% ± 0.07%. The intraclass correlation coefficient was 0.97 (95% CI, 0.96-0.98).

CONCLUSIONS

In clinical practice, the healthy contralateral side can be used as a reference during a real-time musculoskeletal US evaluation of small (<2-mm) structures.

Для цитирования: Rossi Federica, Romano Nicola, Muda Alessandro, Martinoli Carlo, Tagliafico Alberto. Wrist and Hand Ultrasound: Reliability of Side-to-Side Comparisons of Very Small (<2-mm) Clinically Relevant Anatomic Structures.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2018. DOI: 10.1002/jum.14635.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.