MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/13860291251375286

Медицинская библиотека · Clinical hemorheology and microcirculation · 2025

Alterations in erythrocyte deformability, aggregation, and blood viscosity in rheumatoid arthritis and systemic lupus erythematosus patients: A comparative haemorheological analysis.

Helvacı Nazlı, Sari-Ak Duygu, Çam Ergin, Kural Alev, Gundogdu Barıs, Dogantekin Betul

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

ObjectivesThis study investigated haemorheological alterations in patients with rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE).MethodsA total of 136 individuals were enrolled, comprising 52 healthy controls, 51 RA patients, and 33 SLE patients. Blood samples were collected at the University of Health Sciences Sultan Abdulhamid Han Training and Research Hospital in Istanbul, Türkiye. Whole blood and plasma viscosity, along with red blood cell (RBC) deformability and aggregation, were analysed using a Brookfield viscometer and a laser-assisted optical rotational cell analyser (LORRCA).ResultsRBC deformability was reduced in both patient groups compared to controls (EImax: RA 0.645, SLE 0.642, control 0.648), while RBC aggregation was markedly increased (AI: RA 75.66, SLE 74.73, control 65.5) (p < 0.05). Plasma and whole blood viscosity were also elevated in RA and SLE groups, with the highest values observed in SLE patients (PV: RA 1.43, SLE 1.48, control 1.31).ConclusionsRA and SLE patients show notable impairments in haemorheological parameters. Evaluating RBC deformability, aggregation, and plasma viscosity may help clarify disease mechanisms and guide therapeutic strategies to mitigate vascular complications and tissue damage in autoimmune disorders.

Для цитирования: Helvacı Nazlı, Sari-Ak Duygu, Çam Ergin, Kural Alev, Gundogdu Barıs, Dogantekin Betul. Alterations in erythrocyte deformability, aggregation, and blood viscosity in rheumatoid arthritis and systemic lupus erythematosus patients: A comparative haemorheological analysis.. Clinical hemorheology and microcirculation. 2025. DOI: 10.1177/13860291251375286.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.