MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.l.01522

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2013

Lateral mass screw fixation in the cervical spine: a systematic literature review.

Coe Jeffrey D, Vaccaro Alexander R, Dailey Andrew T, Skolasky Richard L, Sasso Richard C, Ludwig Steven C, Brodt Erika D, Dettori Joseph R

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Lateral mass screw fixation with plates or rods has become the standard method of posterior cervical spine fixation and stabilization for a variety of surgical indications. Despite ubiquitous usage, the safety and efficacy of this technique have not yet been established sufficiently to permit "on-label" U.S. Food and Drug Administration approval for lateral mass screw fixation systems. The purpose of this study was to describe the safety profile and effectiveness of such systems when used in stabilizing the posterior cervical spine.

METHODS

A systematic search was conducted in MEDLINE and the Cochrane Collaboration Library for articles published from January 1, 1980, to December 1, 2011. We included all articles evaluating safety and/or clinical outcomes in adult patients undergoing posterior cervical subaxial fusion utilizing lateral mass instrumentation with plates or rods for degenerative disease (spondylosis), trauma, deformity, inflammatory disease, and revision surgery that satisfied our a priori inclusion and exclusion criteria.

RESULTS

Twenty articles (two retrospective comparative studies and eighteen case series) satisfied the inclusion and exclusion criteria and were included. Both of the comparative studies involved comparison of lateral mass screw fixation with wiring and indicated that the risk of complications was comparable between treatments (range, 0% to 7.1% compared with 0% to 6.3%, respectively). In one study, the fusion rate reported in the screw fixation group (100%) was similar to that in the wiring group (97%). Complication risks following lateral mass screw fixation were low across the eighteen case series. Nerve root injury attributed to screw placement occurred in 1.0% (95% confidence interval, 0.3% to 1.6%) of patients. No cases of vertebral artery injury were reported. Instrumentation complications such as screw or rod pullout, screw or plate breakage, and screw loosening occurred in <1% of the screws inserted. Fusion was achieved in 97.0% of patients across nine case series.

CONCLUSIONS

The risks of complications were low and the fusion rate was high when lateral mass screw fixation was used in patients undergoing posterior cervical subaxial fusion. Nerve root injury attributed to screw placement occurred in only 1% of 1041 patients. No cases of vertebral artery injury were identified in 758 patients. Screw or rod pullout, screw or plate breakage, and screw loosening occurred in <1% of the screws inserted.

Для цитирования: Coe Jeffrey D, Vaccaro Alexander R, Dailey Andrew T, Skolasky Richard L, Sasso Richard C, Ludwig Steven C, Brodt Erika D, Dettori Joseph R. Lateral mass screw fixation in the cervical spine: a systematic literature review.. The Journal of bone and joint surgery. American volume. 2013. DOI: 10.2106/jbjs.l.01522.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.