MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0021-9290(03)00011-3

Медицинская библиотека · Journal of biomechanics · 2003

The primary stability of a cementless stem varies between subjects as much as between activities.

Pancanti Alberto, Bernakiewicz Marek, Viceconti Marco

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The rehabilitation program adopted immediately after a cementless total hip replacement is a very important factor, because of the known relationship between osseointegration and implant micromotion. The present study was aimed to evaluate which type of task is the most critical in terms of bone-implant relative micromotion. Both inter-task and inter-subject variability were taken into account to verify if the movement strategy could be determinant on this assessment. A previously validated finite element model was used to predict the peak total micromovements over the entire bone-implant contact surface in four different patients, performing nine different tasks, using published data on joint forces recorded by instrumented hip prostheses. The results predicted by the various simulations suggest that while stair climbing is surely a critical task for primary stability, for some subjects other tasks may be as critical as stair climbing. From a variance analysis for simple crossover design on the predicted peak micromotion, the inter-subject variability had much more influence on the primary stability of cementless implant than the inter-task variability. Even if the results of Patient IBL, who was reported to have difficulties to perform any activities in a normal way, were excluded from the statistical analysis, the inter-subject variability remained still higher than the inter-task variability. The results obtained from simulations suggest that the strategy the hip replacement patient adopts to perform a given motor task, may be, for the implant stability, equally or even more critical than the type of motor task performed.

Для цитирования: Pancanti Alberto, Bernakiewicz Marek, Viceconti Marco. The primary stability of a cementless stem varies between subjects as much as between activities.. Journal of biomechanics. 2003. DOI: 10.1016/s0021-9290(03)00011-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.