MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jspd.2014.07.001

Медицинская библиотека · Spine deformity · 2015

Safety and Efficacy of Power-Assisted Pedicle Tract Preparation and Screw Placement.

Seehausen Derek A, Skaggs David L, Andras Lindsay M, Javidan Yashar

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective review of 1 surgeon's posterior spinal fusion cases.

OBJECTIVES

To assess the safety and efficacy of using power tools versus using manual tools to create pedicle tracts and place pedicle screws.

SUMMARY OF BACKGROUND DATA: This is the first study to report on the safety and efficacy of pedicle tract creation and pedicle screw placement using power tools.

METHODS

The study included 442 cases and 6412 pedicle screws. The manual tool cohort included 159 cases (1,870 screws, January 1, 2004 to June 30, 2007). The power tool cohort included 283 cases (4,542 screws, January 1, 2008 to August 29, 2012). Patient charts and radiographs were reviewed. The researchers recorded the number of screws placed and their positions. Screws were classified as failed if the patient returned to surgery for revision or removal of the screw. Operating and fluoroscopy times were analyzed by cohort overall and for diagnosis-specific subsets.

RESULTS

The incidence of injury resulting from pedicle screw placement was 0.00% (0 of 1,870) with the manual method and 0.02% (1 of 4,542) with power (p = .5211). One screw, placed with power, was assumed to have caused a minor hemothorax, which was successfully treated with a chest tube. There were no neurologic or vascular injuries or other complications attributable to a pedicle screw in either group. Screws placed with power were removed or revised because of problems attributable to the pedicle screw one-sixth as often as those placed using manual tools: 2 of 1,410 (0.14%) versus 8 of 948 (0.84%) (p = .024). Fluoroscopy times in the power cohort were two-thirds as long as those in the manual cohort (p < .001). Operating times were not significantly different (p = .109).

CONCLUSIONS

The use of power tools to create pedicle tracts and place pedicle screws was associated with shorter fluoroscopy times and a lower revision rate compared with using manual tools. Both techniques posed similar low risks of injury to the patient.

Для цитирования: Seehausen Derek A, Skaggs David L, Andras Lindsay M, Javidan Yashar. Safety and Efficacy of Power-Assisted Pedicle Tract Preparation and Screw Placement.. Spine deformity. 2015. DOI: 10.1016/j.jspd.2014.07.001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.